Optimization of Chest CT Radiation Dose in Patients with Covid-19 Pneumonia

Optimization of Chest CT Radiation Dose in Patients with Covid-19 Pneumonia


چاپ صفحه
پژوهان
صفحه نخست سامانه
نویسندگان
نویسندگان
اطلاعات تفضیلی
اطلاعات تفضیلی
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: ناهیده قره آغاجی , صهبا مفضل

عنوان کنگره / همایش: 2nd International Iranian Radiology Students Congress , Iran (Islamic Republic) , سبزوار , 2022

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله ناهیده قره آغاجی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده پیراپزشکی
کد مقاله 80529
عنوان فارسی مقاله Optimization of Chest CT Radiation Dose in Patients with Covid-19 Pneumonia
عنوان لاتین مقاله Optimization of Chest CT Radiation Dose in Patients with Covid-19 Pneumonia
نوع ارائه پوستر
عنوان کنگره / همایش 2nd International Iranian Radiology Students Congress
نوع کنگره / همایش بین المللی
کشور محل برگزاری کنگره/ همایش Iran (Islamic Republic)
شهر محل برگزاری کنگره/ همایش سبزوار
سال انتشار/ ارائه شمسی 1401
سال انتشار/ارائه میلادی 2022
تاریخ شمسی شروع و خاتمه کنگره/همایش 1401/06/28 الی 1401/06/30
آدرس لینک مقاله/ همایش در شبکه اینترنت
آدرس علمی (Affiliation) نویسنده متقاضی Department of Radiology, Faculty of Allied Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran

نویسندگان
hide/show

نویسنده نفر چندم مقاله
ناهیده قره آغاجیاول
صهبا مفضلدوم

اطلاعات تفضیلی
hide/show

عنوان متن
خلاصه مقالهCoronavirus (Covid-19), first reported in Wuhan, China, in December 2019, rapidly involved different communities and countries. CT scan is the gold standard imaging modality to detect the lungs’ involvement with the coronavirus. Due to the high sensitivity, wide availability, and short time to receive the results, demand for chest CT in the diagnosis of Covid-19 pneumonia has increased, especially when the patient needs to be exposed to radiation several times for follow-up which increases the cancer risk. Therefore, optimizing the patients’ radiation dose while maintaining image quality is essential. This study aimed to review the papers related to the optimization of chest CT radiation dose in patients with Covid-19 pneumonia. For this purpose, the articles in PubMed, Google Scholar, and AltaVista search engines were searched with the keywords 'Covid-19', 'optimization', 'radiation dose', and 'chest CT'. Then the relevant papers were analyzed. Based on the findings, various factors affect the chest CT radiation dose and the quality of the CT images including kVp, mAs, pitch, and iterative algorithm. Using the low-dose and ultra-low-dose CT protocols instead of conventional scans can reduce the radiation dose of the patients. The results of one study showed that the low-dose CT protocol reduced the effective dose from 1.8074 mSv in the conventional CT protocol to 0.203 mSv, and the images had excellent quality in the diagnosis of Covid-19 pneumonia. In another study, it was shown that the radiation dose was reduced from 7 mSv in the conventional chest CT scan protocol to 1-1.5 and 0.3 mSv in the low-dose CT and ultra-low-dose CT protocols, respectively. Optimizing chest CT radiation dose in Covid-19 patients and using low-dose and ultra-low-dose CT protocols significantly reduce the patient dose while maintaining the image quality.
کلمات کلیدیCovid-19, optimization, radiation dose, chest CT

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Abstract.JPG1401/10/0480218دانلود
Certificate.pdf1401/10/04430218دانلود