Comparison of 2 Methods of Acromioclavicular Joint Dislocation Fixation With Both Row Screw and Hook Plate

Comparison of 2 Methods of Acromioclavicular Joint Dislocation Fixation With Both Row Screw and Hook Plate


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: کامیار آئین فر , علی صدیقی , حسین اصلانی

کلمات کلیدی: Acromioclavicular dislocation, Hook plate, Screw, Device failure, Range of motion

نشریه: 0 , 3 , 7 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله علی صدیقی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه واحد توسعه تحقیقات بالینی
کد مقاله 78981
عنوان فارسی مقاله Comparison of 2 Methods of Acromioclavicular Joint Dislocation Fixation With Both Row Screw and Hook Plate
عنوان لاتین مقاله Comparison of 2 Methods of Acromioclavicular Joint Dislocation Fixation With Both Row Screw and Hook Plate
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق) Crescent Journal of Medical and Biological Sciences
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Objectives: Acromioclavicular joint (ACJ) dislocation is one of the most common shoulder injuries, especially in young and athletes, which has a significant effect on a patient’s function. Therapeutic strategies include non-surgical and a variety of surgical methods. Each of the 2 therapies has some advantages and disadvantages and careful decision making regarding the appropriate therapeutic approach in these patients has not been achieved due to controversial results. Standard surgical treatment is not specified as well. In this regard, the present study was conducted to compare both row screw and hook plate. Materials and Methods: In this retrospective cohort study, 68 patients were enrolled after referring to the Shohada Medical Education Center of Tabriz during 2014-2017 with the dislocation of the 4th, 5th, and 6th grade ACJ dislocation. In this study, 44 and 24 patients underwent open reduction and internal fixation with a screw and a hook plate, respectively. The retest workers, and the shoulder range of motion (ROM), as well as pain and device failure were compared between the 2 groups. Results: According to the results, there were no significant differences between 68 patients with acute dislocation of ACJ type 4, 5, and 6 in terms of work time and pain intensity in the 2 groups (P=0.78 and P=0.29), but in the examination of ROM, abduction, forward flexion, and external rotation had significantly higher limitations in hook plate compared to the screw (P=0.03, P=0.001, and P=0.02). The maximum motion limitation was observed in shoulder abduction, but the internal rotation between the 2 groups was not significantly different. Eventually, the device failure rate for the screw was significantly higher and approximately 18.4% whereas there was no device failure in hook plate fixation. Conclusions: Based on the present results regarding acromioclavicular dislocation, surgical treatment using a screw showed better functional improvement in comparison to the hook plate although the probability of devise failure was higher.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
کامیار آئین فراول
علی صدیقیدوم
حسین اصلانیسوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
GHA50003620200317.pdf1401/04/04673973دانلود