A Comparison of Conventional Empirical Formula and MCNPX Code in the Estimations of Photon and Neutron Skyshine Rates for an 18MV Radiotherapy Bunker

A Comparison of Conventional Empirical Formula and MCNPX Code in the Estimations of Photon and Neutron Skyshine Rates for an 18MV Radiotherapy Bunker


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: رضا اقدام ضمیری , حسین غیاثی

کلمات کلیدی: Skyshine; Monte Carlo; Photon; Neutron

نشریه: 0 , 4 , 8 , 2021

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله حسین غیاثی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه تیم های تحقیقاتی دانشگاه
کد مقاله 78678
عنوان فارسی مقاله A Comparison of Conventional Empirical Formula and MCNPX Code in the Estimations of Photon and Neutron Skyshine Rates for an 18MV Radiotherapy Bunker
عنوان لاتین مقاله A Comparison of Conventional Empirical Formula and MCNPX Code in the Estimations of Photon and Neutron Skyshine Rates for an 18MV Radiotherapy Bunker
ناشر 2
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق) Frontiers in biomedical technologies
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح سه – Scopus
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Purpose: A physical phenomenon, scattering the radiation by the atmosphere above the room to the points at ground level around the linac treatment room is known as skyshine radiation. This study aimed to estimate photon and neutron skyshine from a linac in a high-energy radiation therapy facility. Materials and Methods: The empirical method of NCRP report 151 and MC simulations were employed to estimate skyshine radiation dose from the 18MV linac photon beam. A linac and its bunker were modeled and skyshine dose equivalent from photons and secondary neutrons were derived and compared in the control room, corridor, sidewalk and, parking. Results: The photon skyshine dose rates calculations by the MC method varied from 0.43 μSv/h at the sidewalk to 6.2 μSv/h at the control room. The ratios of NCRP to MCNP calculations varied from 3.58 for the corridor to 16.14 for the control room. For the neutron skyshine dose rate at distances shorter than 20m, it was found to be 10.4 nSv/h and the ratios of the NCRP to MCNP were 1.26 at the control room and 3.34 at the sidewalk. Conclusion: It was concluded that the empirical method overestimates photon and neutron skyshine dose rates in comparison to the MCNPX code. The refinement of the proposed empirical method of NCRP 151 and application of MC methods are strongly suggested for more reliable calculations of skyshine radiations.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
رضا اقدام ضمیریاول
حسین غیاثیدوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Zamiri et al.pdf1401/02/21532314دانلود