Evaluation of shear bond strength of zirconia to composite resin using different adhesive systems

Evaluation of shear bond strength of zirconia to composite resin using different adhesive systems


چاپ صفحه
پژوهان
صفحه نخست سامانه
نویسندگان
نویسندگان
اطلاعات تفضیلی
اطلاعات تفضیلی
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: ثنا دیبازر

عنوان کنگره / همایش: 4th International Conference on Dental and Clinical Dentistry , Germany , برلین , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله ثنا دیبازر
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 78003
عنوان فارسی مقاله Evaluation of shear bond strength of zirconia to composite resin using different adhesive systems
عنوان لاتین مقاله Evaluation of shear bond strength of zirconia to composite resin using different adhesive systems
نوع ارائه پوستر
عنوان کنگره / همایش 4th International Conference on Dental and Clinical Dentistry
نوع کنگره / همایش بین المللی
کشور محل برگزاری کنگره/ همایش Germany
شهر محل برگزاری کنگره/ همایش برلین
سال انتشار/ ارائه شمسی 1398
سال انتشار/ارائه میلادی 2019
تاریخ شمسی شروع و خاتمه کنگره/همایش 1398/04/17 الی 1398/04/18
آدرس لینک مقاله/ همایش در شبکه اینترنت
آدرس علمی (Affiliation) نویسنده متقاضی Ahvaz Jundishapur University of Medical Sciences, Iran

نویسندگان
hide/show

نویسنده نفر چندم مقاله
ثنا دیبازراول

اطلاعات تفضیلی
hide/show

عنوان متن
کلمات کلیدی10-MDP–shear bond strength–Universal adhesive systems–zirconia primer
خلاصه مقالهBackground: To evaluate shear bond strength of zirconia to composite resin using different universal and conventional adhesives and a zirconia primer. Materials and Methods: Forty zirconia blocks were fabricated of zirconium ingots (10×10×5 mm) and sintered at 1530°C for 2 hours. They were then air-abraded with Al2 O3 particles. The specimens were divided into 4 groups and subjected to one of the following bonding agents: Futurabond U (group 1), Clearfil Universal Bond, universal adhesives (group 2), Z-Prime Plus, zirconia primer (group 3) and Adper Single Bond 2, conventional adhesive (group 4). Composite resin was then applied in a diameter of 5 mm and in a thickness of 2 mm. All the specimens were stored in distilled water at 37°C for 24 hours and then thermocycled between 5°C and 55°C for 5000 cycles with a 30-second dwell time. The shear bond strength was then evaluated with a universal testing machine at a crosshead speed of 1 mm/min. Data (MPa) were analyzed using ANOVA and LSD test (P≤0.05). The specimens were evaluated under a stereomicroscope to determine the mode of failure. Results: The mean shear bond strength was 16,874 MPa in group I, 13.4434 MPa in group II, 11.6500 MPa in group III and 6.8700 MPa in group IV. ANOVA revealed that the shear bond strength in group IV was significantly lower than that in other groups (P≤0.05). Conclusion: The shear bond strength in group I was significantly higher than that in groups III and IV. So Universal adhesives could provide higher shear bond strength of zirconia to composite resin after thermocycling compared to zirconia primers

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
evaluation-of-shear-bond-strength-of-zirconia-to-composite.pdf1400/11/13224879دانلود
evaluation-of-shear-bond-strength-of-zirconia-to-composite.pdf1400/11/13224879دانلود