Assessment of the Effect of Nano Composite Shield on Radiation Risk Prevention to Breast During Computed Tomography

Assessment of the Effect of Nano Composite Shield on Radiation Risk Prevention to Breast During Computed Tomography


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: پریناز محنتی , رضا ملک زاده , بهارک دیوبند , محمد یوسفی سوته

کلمات کلیدی: Nano Bismuth Oxide, Composite Shield, Breast Cancer, Image Quality

نشریه: 16499 , 1 , 17 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله پریناز محنتی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده پزشکی
کد مقاله 77517
عنوان فارسی مقاله Assessment of the Effect of Nano Composite Shield on Radiation Risk Prevention to Breast During Computed Tomography
عنوان لاتین مقاله Assessment of the Effect of Nano Composite Shield on Radiation Risk Prevention to Breast During Computed Tomography
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Background: Application of nanomaterial has recently been introduced as a novel method to make a radiation shield to protect biological damage. Objectives: The purpose of this study was to evaluate the effectiveness regarding the use of Nano shield on the protection of the breast in chest CT scan. MaterialsandMethods: Bismuthoxide nanoparticles were preparedandsynthesized in the Chemistry Laboratory of the University of Tabriz. Special tests were used to evaluate the properties of nanoparticles. Then, nano-bismuth oxide shields were designed with the silicon matrix at 10% and 15% ratios in 0.5- and 1-mm thicknesses, respectively. The dosimetry process was performed by thermoluminescent dosimeters (TLD) dosimeters in the skin and fourth layers of the breast in the chest CT scan. Also, signals and noises of the images were obtained to assess the effects of shield on image quality. Nano particles size was equal to 24 nm and they were spherical in shape. The distribution of nanoparticles in the silicone matrix was approved by scanning electron microscope energy dispersive spectroscopy (SEM-EDS). Results: Nano bismuth shields reduced the dose value by 9% and 15% in the skin layer related to 10% and 15% bismuth nanoparticles ratio (0.5 mm thickness), respectively. Also, by increasing shield thickness to 1 mm, the dose of skin layer was reduced by 18% and 24% related to 10% and 15% of bismuth nanoparticles ratio, respectively. Analysis of CT image showed a 10% increase in the noise related to the 10% bismuth shield. Conclusion: Thenanobismuthcomposite shield with different ratiosandthicknessesshowsignificant dose reduction in the breast. This could play a role in breast cancer prevention during chest CT scan.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
پریناز محنتیاول
رضا ملک زادهدوم
بهارک دیوبندسوم
محمد یوسفی سوتهچهارم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
2020 Assessment of the Effect of Nano Composite Shield on Radiation Risk-iranjradiol-17-1-96002.pdf1400/09/132059044دانلود
tavib payannameh.pdf1400/09/14142419دانلود