Comparison of organic and deep eutectic solvents based dispersive liquid–liquid microextraction for the analysis of phytosterols in cow milk combined with high-performance liquid chromatography-ultraviolet detector

Comparison of organic and deep eutectic solvents based dispersive liquid–liquid microextraction for the analysis of phytosterols in cow milk combined with high-performance liquid chromatography-ultraviolet detector


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: امید همائی , محمدرضا افشار مقدم , ال ناز تمیزی , محبوب نعمتی

کلمات کلیدی: deep eutectic solvents, dispersive liquid–liquid microextraction, high-performance liquid chromatography, phytosterol

نشریه: 55358 , 22 , 44 , 2021

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محبوب نعمتی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات ایمنی غذا و دارو
کد مقاله 77404
عنوان فارسی مقاله Comparison of organic and deep eutectic solvents based dispersive liquid–liquid microextraction for the analysis of phytosterols in cow milk combined with high-performance liquid chromatography-ultraviolet detector
عنوان لاتین مقاله Comparison of organic and deep eutectic solvents based dispersive liquid–liquid microextraction for the analysis of phytosterols in cow milk combined with high-performance liquid chromatography-ultraviolet detector
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

In the present work, a dispersive liquid–liquid microextraction approach has been developed for extraction of four phytosterols (stigmasterol, β-sitosterol, campesterol, and brassicasterol) from cow milk samples using organic and deep eutectic solvents and the results were critically compared. The extracted analytes were determined using high performance liquid chromatography. In the developed method, carbon tetrachloride and choline chloride:p-chlorophenol deep eutectic solvent were selected to use as the best extraction solvent. Effective parameters and validation data were studied for both methods, independently. Under optimum conditions, limits of detection and quantification were within the ranges of 0.3–0.9 and 1.0–3.0 ng/mL for organic solvent based dispersive liquid–liquid microextraction and 0.09–0.32 and 0.3–1.0 ng/mL for deep eutectic solvent based dispersive liquid–liquid microextraction, respectively. Good coefficient of determinations and relative standard deviations obtained for the methods were ≥0.994 and ≤7.6%, respectively. The introduced method was performed on different milk samples for the determination of target analytes using both solvents and the results were analyzed statistically by the t-test.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
امید همائیاول
محمدرضا افشار مقدمدوم
ال ناز تمیزیسوم
محبوب نعمتیچهارم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Homaie-JSS.pdf1400/08/292527530دانلود