Comparison of organic and deep eutectic solvents based dispersive liquid–liquid microextraction for the analysis of phytosterols in cow milk combined with high-performance liquid chromatography-ultraviolet detector
Comparison of organic and deep eutectic solvents based dispersive liquid–liquid microextraction for the analysis of phytosterols in cow milk combined with high-performance liquid chromatography-ultraviolet detector
نویسندگان: امید همائی , محمدرضا افشار مقدم , ال ناز تمیزی , محبوب نعمتی
کلمات کلیدی: deep eutectic solvents, dispersive liquid–liquid microextraction, high-performance liquid chromatography, phytosterol
نشریه: 55358 , 22 , 44 , 2021
| نویسنده ثبت کننده مقاله |
محبوب نعمتی |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات ایمنی غذا و دارو |
| کد مقاله |
77404 |
| عنوان فارسی مقاله |
Comparison of organic and deep eutectic solvents based dispersive liquid–liquid microextraction for the analysis of phytosterols in cow milk combined with high-performance liquid chromatography-ultraviolet detector |
| عنوان لاتین مقاله |
Comparison of organic and deep eutectic solvents based dispersive liquid–liquid microextraction for the analysis of phytosterols in cow milk combined with high-performance liquid chromatography-ultraviolet detector |
| ناشر |
4 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
خیر |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| In the present work, a dispersive liquid–liquid microextraction approach has
been developed for extraction of four phytosterols (stigmasterol, β-sitosterol,
campesterol, and brassicasterol) from cow milk samples using organic and deep
eutectic solvents and the results were critically compared. The extracted analytes were determined using high performance liquid chromatography. In the
developed method, carbon tetrachloride and choline chloride:p-chlorophenol
deep eutectic solvent were selected to use as the best extraction solvent. Effective
parameters and validation data were studied for both methods, independently.
Under optimum conditions, limits of detection and quantification were within
the ranges of 0.3–0.9 and 1.0–3.0 ng/mL for organic solvent based dispersive
liquid–liquid microextraction and 0.09–0.32 and 0.3–1.0 ng/mL for deep eutectic
solvent based dispersive liquid–liquid microextraction, respectively. Good coefficient of determinations and relative standard deviations obtained for the methods were ≥0.994 and ≤7.6%, respectively. The introduced method was performed
on different milk samples for the determination of target analytes using both solvents and the results were analyzed statistically by the t-test. |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| Homaie-JSS.pdf | 1400/08/29 | 2527530 | دانلود |