A polymer-based dispersive solid phase extraction combined with deep eutectic solvent based-dispersive liquid–liquid microextraction for the determination of four hydroxylated polycyclic aromatic hydrocarbons from urine samples

A polymer-based dispersive solid phase extraction combined with deep eutectic solvent based-dispersive liquid–liquid microextraction for the determination of four hydroxylated polycyclic aromatic hydrocarbons from urine samples


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: ابوالقاسم جویبان , محبوب نعمتی , علی اکبر علیزاده نبیل , محمدرضا افشار مقدم

کلمات کلیدی: deep eutectic solvents, dispersive liquid–liquid microextraction, dispersive solid phase extraction, gas chromatography–mass spectrometry, polycyclic aromatic hydrocarbons

نشریه: 55358 , 21 , 44 , 2021

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمدرضا افشار مقدم
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات ایمنی غذا و دارو
کد مقاله 77320
عنوان فارسی مقاله A polymer-based dispersive solid phase extraction combined with deep eutectic solvent based-dispersive liquid–liquid microextraction for the determination of four hydroxylated polycyclic aromatic hydrocarbons from urine samples
عنوان لاتین مقاله A polymer-based dispersive solid phase extraction combined with deep eutectic solvent based-dispersive liquid–liquid microextraction for the determination of four hydroxylated polycyclic aromatic hydrocarbons from urine samples
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

A new and efficient extraction procedure was proposed and used for the simultaneous extraction of four hydroxylated metabolites polycyclic aromatic hydrocarbons from urine samples. The extraction procedure was started by dissolving an organic polymer into a water-miscible organic solvent (iso-propanol) and its injection into the sample solution. The sorbent was re-precipitated in all parts of the solution as tiny particles and the analytes were adsorbed onto the sorbent. After that, the sorbent was separated and the adsorbed analytes were eluted by choline chloride: dichloroacetic acid deep eutectic solvent. The elution solvent was mixed with choline chloride-3,3-dimethyl butyric acid deep eutectic solvent and the mixture was applied in dispersive liquid–liquid microextraction procedure for more concentration of the analytes. After optimization, the method validation was followed according to International Council Harmonization guidelines and the results showed that wide linear ranges (26–500 000 ng/L) and low limits of detection (3.6–7.2 ng/L) and quantification (11–26 ng/L) were obtained. Satisfactory enrichment factors (435–475) and extraction recoveries (87–95%), and acceptable relative standard deviations (equal or less than 8.6%) were obtained. Finally, the introduced method was successfully applied for determina

نویسندگان
hide/show

نویسنده نفر چندم مقاله
ابوالقاسم جویباناول
محبوب نعمتیدوم
علی اکبر علیزاده نبیلچهارم
محمدرضا افشار مقدمپنجم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
JSS-HPAHs-2021-metabolinte.pdf1400/08/182307464دانلود