Determination of Bisphenol A in Packed Milk and Mineral Water Samples Marketed in Tabriz (Iran) in 2020 Using High-performance Liquid Chromatography-ultraviolet Detector

Determination of Bisphenol A in Packed Milk and Mineral Water Samples Marketed in Tabriz (Iran) in 2020 Using High-performance Liquid Chromatography-ultraviolet Detector


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: محبوب نعمتی , محمدرضا افشار مقدم , امین رستم زاده

کلمات کلیدی: Bisphenol A, High-performance liquid chromatography, Water, Milk, Dispersive liquid-liquid microextraction

نشریه: 0 , 4 , 8 , 2021

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محبوب نعمتی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات ایمنی غذا و دارو
کد مقاله 77255
عنوان فارسی مقاله Determination of Bisphenol A in Packed Milk and Mineral Water Samples Marketed in Tabriz (Iran) in 2020 Using High-performance Liquid Chromatography-ultraviolet Detector
عنوان لاتین مقاله Determination of Bisphenol A in Packed Milk and Mineral Water Samples Marketed in Tabriz (Iran) in 2020 Using High-performance Liquid Chromatography-ultraviolet Detector
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) Analytical and bioanalytical chemistry Research
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Bisphenol A (BPA) is a monomer used to produce several plastic resins in food storage containers. Residual BPA in plastics can be found in filled foods in containers. Because BPA is an endocrine disruptor, its dietary exposure must be estimated. In this method, the analyte was extracted using a dispersive liquid-liquid microextraction procedure from water and milk samples. For this purpose, a mixture of acetone and chloroform (142 µl) was dispersed in the water sample or in the aqueous phase obtained from milk after its deproteinization with trichloroacetic acid. The obtained cloudy solutions were centrifuged in both samples and the sedimentation phase was analyzed by a high-performance liquid chromatography-ultraviolet detector. Analytical features of the method consist of limits of detection (0.44 ng ml -1 in water and 0.51 ng ml -1 in milk samples) and quantification (1.47 ng ml -1 in water and 1.72 ng ml -1 in milk samples), linearity (r2 = 0.992), precision (RSD ≤ 11.1%), and accuracy (RSD ≤ 3%) were studied under final conditions. The results showed that the obtained results are acceptable. Different milk and water samples were analyzed using the developed method, and BPA was found in several samples in the ranges of 11.2-32.6 and 9.6-23.5 ng ml -1 in milk and water samples, respectively. Comparison of the results with the maximum residue limit established by the European Commission showed that the BPA content exceeded the authorized content.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
محبوب نعمتیدوم
محمدرضا افشار مقدمچهارم
امین رستم زادهاول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
BPA Anal BioAnal 2021.pdf1400/08/12559575دانلود