Trend in creatinine determining methods: Conventional methods to molecular‐based methods

Trend in creatinine determining methods: Conventional methods to molecular‐based methods


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: سید حسین راستا , مهداد اسمعیلی , احمد موبدکرکج , حمید طیبی خسروشاهی , رامین نریمانی

کلمات کلیدی: biomarker, biosensor, electrochemical, enzyme, molecular imprinted polymer, nanoparticle

نشریه: 0 , 2021 , 2 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله احمد موبدکرکج
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه معاونت ها و پژوهشکده های دانشگاه
کد مقاله 77166
عنوان فارسی مقاله Trend in creatinine determining methods: Conventional methods to molecular‐based methods
عنوان لاتین مقاله Trend in creatinine determining methods: Conventional methods to molecular‐based methods
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) Analytical Science Advances
نوع مقاله Review Article
نحوه ایندکس شدن مقاله ایندکس نشده
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Renal failure (RF) disease is ranked as one of the most prevalent diseases with severe morbidity and mortality. Early diagnosis of RF leads to subsequent control of disease to reduce the poor prognosis. The level of sera creatinine is considered as a significant biomarker for kidney biofunction, which is routinely detected by the Jaffe reaction. The normal range for creatinine in the blood may be 0.84-1.21 mg/dL. Low accuracy, insufficient sensitivity, explosive and toxicity of picric acid, and pseudo-interaction with nonspecific elements such as ammonium ions in the Jaffe method lead to the development of various techniques for precise detection of creatinine such as spectroscopic, electrochemical, and chromatography approaches and sensors based on enzymes, molecular imprinted polymer and nanoparticles, etc. Based on previously established results, they are trying to construct sensors with high accuracy, optimum sensitivity, acceptable linear/calibration range, and limit of detection, which are small in size and applicable by the patient him/herself (point-of-care testing). By comparing the results of research, a molecularly imprinted electrochemiluminescence-based sensor with linear/calibration range of 5-1 mM concentration of creatinine and the detection limit of 0.5 nM has the best detectable resolution with 2 million measurable points. In this paper, we will review the recently developed methods for measuring creatinine concentration and renal biofunction.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
سید حسین راستاسوم
مهداد اسمعیلیدوم
احمد موبدکرکجپنجم
حمید طیبی خسروشاهیچهارم
رامین نریمانیاول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
ansa.pdf1400/08/042125360دانلود