Ultrasensitive fluorescence detection of antitumor drug methotrexate based on a terbium-doped silica dendritic probe

Ultrasensitive fluorescence detection of antitumor drug methotrexate based on a terbium-doped silica dendritic probe


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: آرزو محمد زاده , ابوالقاسم جویبان , محمد حسن زاده محله , جعفر سلیمانی

کلمات کلیدی: fluorescence detection, methotrexate, terbium-doped silica dendritic probe

نشریه: 1985 , 2021 , 13 , 2021

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله جعفر سلیمانی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات آنالیز دارویی
کد مقاله 76940
عنوان فارسی مقاله Ultrasensitive fluorescence detection of antitumor drug methotrexate based on a terbium-doped silica dendritic probe
عنوان لاتین مقاله Ultrasensitive fluorescence detection of antitumor drug methotrexate based on a terbium-doped silica dendritic probe
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

A novel strategy was developed for the detection of methotrexate (MTX) via the quenching effect of MTX on the fluorescence intensity of terbium-doped dendritic silica particles (Tb@KCC-1). The fluorescence intensity of Tb@KCC-1 can be effectively quenched by MTX at 546 nm under an excitation wavelength of 233 nm. The quenched fluorescence is proportional to the amount of MTX in both plasma and exhaled breath condensate (EBC) samples. Under the optimal conditions, the linear dynamic ranges of the developed method were 44 nM to 2.2 mM for EBC, 44 nM to 0.22 mM and 0.22–2.2 mM for plasma samples. The limit of detection (LOD) and limit of quantification (LOQ) in both plasma and EBC media are 35 and 116 nM, respectively. The developed method has the benefits of fast analysis time, simple approach, high specificity, and sensitivity for the detection of MTX in both media. This nanoprobe has been successfully utilized for the quantification of MTX in patients' plasma and spiked EBC samples, proving the applicability of the nanoprobe for MTX detection in real samples.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
آرزو محمد زادهاول
ابوالقاسم جویباندوم
محمد حسن زاده محلهسوم
جعفر سلیمانیپنجم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
1.pdf1400/07/08948748دانلود