Comparison of stress distribution pattern in orthodontic bracket- adhesive tooth system during treatment time and deboning stage

Comparison of stress distribution pattern in orthodontic bracket- adhesive tooth system during treatment time and deboning stage


چاپ صفحه
پژوهان
صفحه نخست سامانه
نویسندگان
نویسندگان
اطلاعات تفضیلی
اطلاعات تفضیلی
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: بهنام میرزاکوچکی

عنوان کنگره / همایش: 11th ASME Biennial Conference on Engineering Systems Design and Analysis, (ESDA 2012) , France , Nantes , 2012

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله بهنام میرزاکوچکی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 76931
عنوان فارسی مقاله Comparison of stress distribution pattern in orthodontic bracket- adhesive tooth system during treatment time and deboning stage
عنوان لاتین مقاله Comparison of stress distribution pattern in orthodontic bracket- adhesive tooth system during treatment time and deboning stage
نوع ارائه پوسترو سخنرانی
عنوان کنگره / همایش 11th ASME Biennial Conference on Engineering Systems Design and Analysis, (ESDA 2012)
نوع کنگره / همایش بین المللی
کشور محل برگزاری کنگره/ همایش France
شهر محل برگزاری کنگره/ همایش Nantes
سال انتشار/ ارائه شمسی 1393
سال انتشار/ارائه میلادی 2012
تاریخ شمسی شروع و خاتمه کنگره/همایش 1391/04/12 الی 1391/04/14
آدرس لینک مقاله/ همایش در شبکه اینترنت https://www1.wosgs.ir/full_record.do?product=WOS&search_mode=GeneralSearch&qid=2&SID=D1jx9cu3FRBPFsOokOg&page=1&doc=15
آدرس علمی (Affiliation) نویسنده متقاضی Tabriz University of medical sciences

نویسندگان
hide/show

نویسنده نفر چندم مقاله
بهنام میرزاکوچکیسوم

اطلاعات تفضیلی
hide/show

عنوان متن
خلاصه مقالهFixed orthodontic treatment is based on effective bonding of bracket to enamel surface. During orthodontic therapy, load is applied on bracket slot by orthodontic wire, and then it is transferred to adhesive layer and enamel surface (state I). After the completion of treatment period, orthodontic brackets are debonded by load application on the incisal region of bracket-adhesive-interface (state II). In order to compare the diversity in stress distribution pattern of these two states, micro CT images of maxillary premolar tooth and bracket were transformed to STL files and imported to Hypermesh software to create high quality 3D finite element models. Space between enamel and bracket was filled with orthodontic adhesive material which sets to 0.2 mm at thickest region. Mechanical property was assigned to each layer and appropriate boundary conditions were applied. By using a load distributing element RBE3, firstly 150 N shear load was applied on the bracket slot to simulate bracket-adhesive-tooth system of state I and secondly the same load was applied on the incisal area of bracket and bracket-adhesive bonding to simulate bracket-adhesive-tooth system of state II. Generated stresses on the bracket, the adhesive and the tooth in both systems were obtained and compared to each other. The Findings of this study, reveal that the effect of bonding loads was directly transform to the adhesive layer and the enamel surface; hence, treatment period would decrease. Alternatively, debonding loads would bring about higher stresses on the bracket and facilitate debonding action.
کلمات کلیدیStress distribution; Treatment time; Debonding stage; Bracket-adhesive-tooth system

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Untitled.pdf1400/07/07661941دانلود
mmmm.png1400/07/07254810دانلود
99.docx1400/07/14219573دانلود