In-situ formation of a hydrophobic deep eutectic solvent based on alpha terpineol and its application in liquid-liquid microextraction of three β-blockers from plasma samples

In-situ formation of a hydrophobic deep eutectic solvent based on alpha terpineol and its application in liquid-liquid microextraction of three β-blockers from plasma samples


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: ابوالقاسم جویبان , محمدرضا افشار مقدم , محبوب نعمتی , مریم خوب نسب جعفری

کلمات کلیدی: Liquid-liquid microextraction Deep eutectic solvent Plasma Gas chromatography–mass spectrometry

نشریه: 24084 , 106677 , 170 , 2021

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمدرضا افشار مقدم
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات ایمنی غذا و دارو
کد مقاله 76524
عنوان فارسی مقاله In-situ formation of a hydrophobic deep eutectic solvent based on alpha terpineol and its application in liquid-liquid microextraction of three β-blockers from plasma samples
عنوان لاتین مقاله In-situ formation of a hydrophobic deep eutectic solvent based on alpha terpineol and its application in liquid-liquid microextraction of three β-blockers from plasma samples
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

A new microextraction procedure based on liquid-liquid microextraction using a deep eutectic solvent has been used for the extraction of three β-blockers (atenolol, propranolol, and metoprolol) from plasma samples. The enriched analytes were analyzed by gas chromatography-mass spectrometry. In this study, both of the microextraction and synthesis processes were accelerated by using microwave radiations. In this procedure, 5 mL diluted plasma sample was transferred into a glass test tube and it was mixed with 0.20 g tetramethylammonium chloride. Then 0.5 mL of dimethylformamide (as a co-disperser) was mixed with 610 µL alpha terpineol and the mixture was dispersed into the solution to form a homogenous solution. The tube was placed under microwave radiations for 1 min. By doing so, tetramethylammonium chloride-alpha terpineol deep eutectic solvent was formed in sample solution as tiny droplets and the analytes were extracted into them. Then the tube was cooled with tap water and centrifuged for 5 min at 5000 rpm. Finally 1 µL of the deep eutectic solvent was injected into the determination system. Low limits of detection (0.130–0.205 ng mL− 1 ) and quantification (0.435–0.692 ng mL− 1 ), high extraction recovery (72–86%), and good precision (relative standard deviation ≤ 5.3%) were obtained. The introduced method was effectively applied for determination of the β-blockers’ concentrations in plasma samples

نویسندگان
hide/show

نویسنده نفر چندم مقاله
ابوالقاسم جویباناول
محمدرضا افشار مقدمدوم
محبوب نعمتیپنجم
مریم خوب نسب جعفریششم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
metprolo-2021.pdf1400/05/18852383دانلود