In-situ formation of a hydrophobic deep eutectic solvent based on alpha terpineol and its application in liquid-liquid microextraction of three β-blockers from plasma samples
In-situ formation of a hydrophobic deep eutectic solvent based on alpha terpineol and its application in liquid-liquid microextraction of three β-blockers from plasma samples
نویسندگان: ابوالقاسم جویبان , محمدرضا افشار مقدم , محبوب نعمتی , مریم خوب نسب جعفری
کلمات کلیدی: Liquid-liquid microextraction
Deep eutectic solvent
Plasma
Gas chromatography–mass spectrometry
نشریه: 24084 , 106677 , 170 , 2021
| نویسنده ثبت کننده مقاله |
محمدرضا افشار مقدم |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات ایمنی غذا و دارو |
| کد مقاله |
76524 |
| عنوان فارسی مقاله |
In-situ formation of a hydrophobic deep eutectic solvent based on alpha terpineol and its application in liquid-liquid microextraction of three β-blockers from plasma samples |
| عنوان لاتین مقاله |
In-situ formation of a hydrophobic deep eutectic solvent based on alpha terpineol and its application in liquid-liquid microextraction of three β-blockers from plasma samples |
| ناشر |
6 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| A new microextraction procedure based on liquid-liquid microextraction using a deep eutectic solvent has been
used for the extraction of three β-blockers (atenolol, propranolol, and metoprolol) from plasma samples. The
enriched analytes were analyzed by gas chromatography-mass spectrometry. In this study, both of the microextraction and synthesis processes were accelerated by using microwave radiations. In this procedure, 5 mL
diluted plasma sample was transferred into a glass test tube and it was mixed with 0.20 g tetramethylammonium
chloride. Then 0.5 mL of dimethylformamide (as a co-disperser) was mixed with 610 µL alpha terpineol and the
mixture was dispersed into the solution to form a homogenous solution. The tube was placed under microwave
radiations for 1 min. By doing so, tetramethylammonium chloride-alpha terpineol deep eutectic solvent was
formed in sample solution as tiny droplets and the analytes were extracted into them. Then the tube was cooled
with tap water and centrifuged for 5 min at 5000 rpm. Finally 1 µL of the deep eutectic solvent was injected into
the determination system. Low limits of detection (0.130–0.205 ng mL− 1
) and quantification (0.435–0.692 ng
mL− 1
), high extraction recovery (72–86%), and good precision (relative standard deviation ≤ 5.3%) were obtained. The introduced method was effectively applied for determination of the β-blockers’ concentrations in
plasma samples |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| metprolo-2021.pdf | 1400/05/18 | 852383 | دانلود |