The Accuracy of Enzyme-Linked Immunosorbent Assay in the Diagnosis of COVID-19 in Iranian Children

The Accuracy of Enzyme-Linked Immunosorbent Assay in the Diagnosis of COVID-19 in Iranian Children


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: وحید طرماحی , محمدرضا افغان , سینا رئیسی , حمید رضا یوسفی نوده , نادر محمدزاده , زکیه عبادی

کلمات کلیدی: Children, COVID-19, Diagnosis, Real-time RT-PCR, SARS-CoV-2

نشریه: 37721 , 7 , 9 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله سینا رئیسی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات سلامت کودکان
کد مقاله 75853
عنوان فارسی مقاله The Accuracy of Enzyme-Linked Immunosorbent Assay in the Diagnosis of COVID-19 in Iranian Children
عنوان لاتین مقاله The Accuracy of Enzyme-Linked Immunosorbent Assay in the Diagnosis of COVID-19 in Iranian Children
ناشر 8
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Background The present study aimed to evaluate the accuracy of enzyme-linked immunosorbent assay (ELISA) compared to the real-time reverse transcription-polymerase chain reaction (rRT-PCR) in the diagnosis of coronavirus disease 2019 (COVID-19) in Iranian children. Materials and Methods In this cross-sectional study, 90 children under 15 years of age were randomly selected from suspects of COVID-19 referred to the Tabriz Children Hospital, the main pediatric COVID-19 diagnostic center of Tabriz, from May 21, 2020 to June 21, 2020. Blood and nasopharyngeal samples were taken simultaneously at the referring time. The diagnostic accuracy of ELISA-based IgM and IgG antibody tests for COVID-19 were compared with the rRT-PCR. Results The calculated sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, negative likelihood ratio, overall diagnostic accuracy, and diagnostic odds ratio were 0.5745, 0.9767, 0.9643, 0.6774, 24.66, 0.4357, 0.7667, and 56.60 for IgM; and 0.6170, 0.9302, 0.9355, 0.6897, 8.84, 0.4117, 0.7667, and 21.47 for IgG, respectively. Conclusion Due to the lower sensitivity of antibody detection-based serological tests compared to rRT-PCR, they cannot be considered as initial and reliable tests for the diagnosis of COVID-19. It can be suggested that the serological tests be only used as complementary tests to rRT-PCR or for monitoring the immune response of children with COVID-19.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
وحید طرماحیاول
محمدرضا افغاندوم
سینا رئیسیسوم
حمید رضا یوسفی نودهچهارم
نادر محمدزادههفتم
زکیه عبادیهشتم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
31-COVID-ELISA.pdf1400/02/26342797دانلود