Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques
Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques
نویسندگان: فرناز منجم زاده
کلمات کلیدی: incompatibility, excipient, gliclazide, differential scanning calorimetry, fourier transform infrared
spectroscopy, high performance liquid chromatography
نشریه: 0 , 2 , 34 , 2021
| نویسنده ثبت کننده مقاله |
فرناز منجم زاده |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات ایمنی غذا و دارو |
| کد مقاله |
75723 |
| عنوان فارسی مقاله |
Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques |
| عنوان لاتین مقاله |
Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques |
| ناشر |
3 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
خیر |
| عنوان نشریه (خارج از لیست فوق) |
ANALYTICAL SCIENCE & TECHNOLOGY |
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| Abstract: Evaluation of drug-excipient compatibility is one of the basic steps in the preformulation of
pharmaceutical dosage forms. Some reactive excipients have been known so far which may cause stability
problems for drug molecules in pharmaceutical dosage forms. The aim of this study was to evaluate drugexcipient
compatibility of gliclazide with some common pharmaceutical excipients, known for their ability to
incorporate in drug-excipient interactions. Binary mixtures were prepared using lactose, magnesium stearate,
polyvinylpyrrolidone, sodium starch glycolate, polyethylene glycol 2000 and dicalcium phosphate. Based on
the results; gliclazide was incompatible with all tested excipients; but not with dicalcium phosphate. DSC
(Differential Scanning Calorimetry) results were in accordance with HPLC (High Pressure liquid chromatography)
data and were more predictive than FTIR (Fourier Transform Infrared Spectroscopy). Drug and reactive
excipients incompatibility was fully discussed and documented. It is advisable to avoid incompatible excipients
or carefully monitor the drug stability when incorporating such excipients in final formulation designs. |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| Final Published-Gliclazide compatibility.pdf | 1400/03/10 | 771944 | دانلود |
| prop-mohammad shabani 001.jpg | 1400/03/10 | 536932 | دانلود |
| link.docx | 1400/03/17 | 11489 | دانلود |