Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques

Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: فرناز منجم زاده

کلمات کلیدی: incompatibility, excipient, gliclazide, differential scanning calorimetry, fourier transform infrared spectroscopy, high performance liquid chromatography

نشریه: 0 , 2 , 34 , 2021

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله فرناز منجم زاده
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات ایمنی غذا و دارو
کد مقاله 75723
عنوان فارسی مقاله Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques
عنوان لاتین مقاله Gliclazide compatibility with some common chemically reactive excipients; using different analytical techniques
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) ANALYTICAL SCIENCE & TECHNOLOGY
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract: Evaluation of drug-excipient compatibility is one of the basic steps in the preformulation of pharmaceutical dosage forms. Some reactive excipients have been known so far which may cause stability problems for drug molecules in pharmaceutical dosage forms. The aim of this study was to evaluate drugexcipient compatibility of gliclazide with some common pharmaceutical excipients, known for their ability to incorporate in drug-excipient interactions. Binary mixtures were prepared using lactose, magnesium stearate, polyvinylpyrrolidone, sodium starch glycolate, polyethylene glycol 2000 and dicalcium phosphate. Based on the results; gliclazide was incompatible with all tested excipients; but not with dicalcium phosphate. DSC (Differential Scanning Calorimetry) results were in accordance with HPLC (High Pressure liquid chromatography) data and were more predictive than FTIR (Fourier Transform Infrared Spectroscopy). Drug and reactive excipients incompatibility was fully discussed and documented. It is advisable to avoid incompatible excipients or carefully monitor the drug stability when incorporating such excipients in final formulation designs.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
فرناز منجم زادهسوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Final Published-Gliclazide compatibility.pdf1400/03/10771944دانلود
prop-mohammad shabani 001.jpg1400/03/10536932دانلود
link.docx1400/03/1711489دانلود