Thermal Stability and Monomer Elution of Bulk Fill Composite Resins Cured from Different Irradiation Distances

Thermal Stability and Monomer Elution of Bulk Fill Composite Resins Cured from Different Irradiation Distances


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: فاطمه پورنقی آذر , صبا ندروند میاندوآب , المیرا جعفری نویمی پور

کلمات کلیدی: Composite Resins; Chromatography, Gas; Triethylene Glycol Dimethacrylate

نشریه: 0 , 9 , 18 , 2021

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله فاطمه پورنقی آذر
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 75521
عنوان فارسی مقاله Thermal Stability and Monomer Elution of Bulk Fill Composite Resins Cured from Different Irradiation Distances
عنوان لاتین مقاله Thermal Stability and Monomer Elution of Bulk Fill Composite Resins Cured from Different Irradiation Distances
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق) Frontiers in Dentistry
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Objectives: This study aimed to evaluate the thermal stability and monomer elution of bulk fill composite resins cured at different irradiation distances. Materials and Methods: Forty cylindrical-shaped (3×4mm) specimens were fabricated from two composite resins (X-tra fil, X-tra base) and cured from 0 and 7mm distances. In 9 specimens, the degree of conversion was determined by the release of monomers. For this purpose, after curing of composites, they were immersed in 5 mL of 99.9% methanol and stored at 37°C for 24h. The eluted monomer was then analyzed by gas chromatography (GC). Also, thermal stability of one sample from each group was assessed by thermogravimetric analysis (TGA) at a rate of 10°C/min. Data were analyzed using two-way ANOVA and Tukey’s post-hoc test (P<0.05). Results: X-tra fil had significantly higher degree of conversion than X-tra base (P=0.001). Specimens cured at 7mm distance had significantly lower degree of conversion compared with those cured at 0 mm distance (P=0.001). The interaction effect of composite type and distance of light curing unit from the surface of samples was statistically significant (P=0.001). Regarding the TGA results, the lowest and the highest percentages of weight loss were detected in X-tra fil cured at 0 mm distance and X-tra base cured at 7mm distance, respectively. Conclusion: X-tra fil composite cured at 0mm distance had the highest degree of conversion and thermal stability, and X-tra base composite cured at 7mm distance had the lowest values.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
فاطمه پورنقی آذردوم
صبا ندروند میاندوآبچهارم
المیرا جعفری نویمی پوراول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
3385.pdf1400/01/151150161دانلود