Microextraction and chromatographic analysis of budesonide epimers in exhaled breath condensate

Microextraction and chromatographic analysis of budesonide epimers in exhaled breath condensate


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: مریم خوب نسب جعفری , وحید جویبان قراملکی , ابوالقاسم جویبان

کلمات کلیدی: Bioanalysis, budesonide, determination, exhaled breath condensate, HPLC-UV, microextraction

نشریه: 8538 , 0 , 16 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله ابوالقاسم جویبان
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات آنالیز دارویی
کد مقاله 73873
عنوان فارسی مقاله Microextraction and chromatographic analysis of budesonide epimers in exhaled breath condensate
عنوان لاتین مقاله Microextraction and chromatographic analysis of budesonide epimers in exhaled breath condensate
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract: Background: Analysis of drug concentrations in biological fluids is required in clinical sciences for various purposes. Among other biological samples, exhaled breath condensate (EBC) is a potential sample for follow up of drug concentrations. Methods: A dispersive liquid-liquid microextraction (DLLME) procedure followed by a validated liquid chromatography method was employed for the determination of budesonide (BDS) in EBC samples collected using a homemade setup. EBC is a non-invasive biological sample with possible applications for monitoring drug concentrations. The proposed analytical method is validated according to the FDA guidelines using EBC-spiked samples. Its applicability is tested on EBC samples collected from healthy volunteers receiving a single puff of BDS. Results: The best DLLME conditions involved the use of methanol (1 mL) as a disperser solvent, chloroform (200 μL) as an extraction solvent, and centrifugation rate of 3500 rpm for 5 minutes. The method was validated over a concentration range of 21-210 μg·L-1 in EBC. Inter- and intra-day precisions were less than 10% where the acceptable levels are less than 20%. The validated method was successfully applied for the determination of BDS in EBC samples. Conclusion: The findings of this study indicate that the developed method can be used for the extraction and quantification of BDS in EBC samples using a low cost method

نویسندگان
hide/show

نویسنده نفر چندم مقاله
مریم خوب نسب جعفریدوم
وحید جویبان قراملکیچهارم
ابوالقاسم جویبانششم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Curr Anal Chem 16 (2020) Budesonide paper - final proof.pdf1399/07/141115410دانلود