Simultaneous application of deep eutectic solvent as extraction solvent and ion-pair agent in liquid phase microextraction for the extraction of biogenic amines from tuna fish samples
Simultaneous application of deep eutectic solvent as extraction solvent and ion-pair agent in liquid phase microextraction for the extraction of biogenic amines from tuna fish samples
نویسندگان: محبوب نعمتی , محمدرضا افشار مقدم , محمدرضا صحت خواه
کلمات کلیدی: Biogenic amine
Deep eutectic solvent
Dispersive liquid–liquid microextraction
High performance liquid chromatography
Tuna fish
نشریه: 24084 , 105496 , 159 , 2020
| نویسنده ثبت کننده مقاله |
محمدرضا افشار مقدم |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات ایمنی غذا و دارو |
| کد مقاله |
73627 |
| عنوان فارسی مقاله |
Simultaneous application of deep eutectic solvent as extraction solvent and ion-pair agent in liquid phase microextraction for the extraction of biogenic amines from tuna fish samples |
| عنوان لاتین مقاله |
Simultaneous application of deep eutectic solvent as extraction solvent and ion-pair agent in liquid phase microextraction for the extraction of biogenic amines from tuna fish samples |
| ناشر |
5 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| An efficient, simple, rapid, and repeatable sample preparation method based on microwave-assisted solvent
extraction combined with dispersive liquid–liquid microextraction using in situ synthesis of a deep eutectic
solvent was developed for the extraction of some biogenic amines in canned tuna fish samples. In this procedure,
one carboxylic acid group of hexanedioic acid is participated in formation of the deep eutectic solvent while the
other one is used to form ion pair with the analytes. Initially the analytes are extracted into deionized water
sample during microwave-assisted solvent extraction. After centrifugation deep eutectic solvent synthesis and the
microextraction procedure are performed simultaneously in the supernatant phase. The enriched analytes are
separated and determined by high performance liquid chromatography-diode array detection. The method
provided low limits of detection and quantification in the ranges of 0.25–0.50 and 0.84–1.7 ng g− 1
, respectively.
The method had a proper repeatability with relative standard deviation less than or equal to 12%. The validated
method was successfully performed on different canned tuna fish samples obtained from different producers. |