Dispersive Micro-Solid Phase Extraction for Sensitive Determination of Methotrexate from Human Saliva Followed by Spectrophotometric Method

Dispersive Micro-Solid Phase Extraction for Sensitive Determination of Methotrexate from Human Saliva Followed by Spectrophotometric Method


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: ثمین حمیدی , فاطمه صغری جاهد دیزجی

کلمات کلیدی: Methotrexate- saliva- dispersive micro solid phase extraction- spectrophotometry

نشریه: 3607 , 6 , 21 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله ثمین حمیدی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات ایمنی غذا و دارو
کد مقاله 73595
عنوان فارسی مقاله Dispersive Micro-Solid Phase Extraction for Sensitive Determination of Methotrexate from Human Saliva Followed by Spectrophotometric Method
عنوان لاتین مقاله Dispersive Micro-Solid Phase Extraction for Sensitive Determination of Methotrexate from Human Saliva Followed by Spectrophotometric Method
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

For biological assessing of hospital personnel occupationally exposed to antineoplastic drugs, highly sensitive and accurate methods are required. Methotrexate (MTX) is an anticancer agent that is widely used in a variety of human cancers. For the first time, dispersive-micro solid phase extraction (D-µ-SPE) has been applied for determination of low levels of MTX in saliva samples. The method is based on rapid extraction of MTX using graphene oxide adsorbent. The sample preparation time is decreased by the fact that the adsorbent dispersed in the sample solution and extraction equilibrium can be reached very fast. This significant feature which obtained with this method is of key interest for routine trace laboratory analysis. The influence of different variables on D-µ-SPE was investigated. Under optimum conditions, the calibration graph was linear over the range of 10–1,000 ng/ml. The relative standard deviations are better than 9.0%. The proposed method was successfully applied for the determination of MTX in patient samples

نویسندگان
hide/show

نویسنده نفر چندم مقاله
ثمین حمیدیدوم
فاطمه صغری جاهد دیزجیاول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
APJCP_Volume 21_Issue 6_Pages 1531-1538.pdf1399/07/02403414دانلود