The effect of pre-heating on monomer elution from bulk-fill resin composites

The effect of pre-heating on monomer elution from bulk-fill resin composites


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: محمد اسماعیل ابراهیمی چهارم , المیرا جعفری نویمی پور , پرنیان علیزاده اسکویی , امیر احمد عجمی , مهدی عابد کهنمویی , محمود بهاری

کلمات کلیدی: Bulk fill composite resin, elution, HPLC, residual monomer, temperature.

نشریه: 19695 , 9 , 12 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمد اسماعیل ابراهیمی چهارم
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 73568
عنوان فارسی مقاله The effect of pre-heating on monomer elution from bulk-fill resin composites
عنوان لاتین مقاله The effect of pre-heating on monomer elution from bulk-fill resin composites
ناشر 8
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Background: The present study was aimed to evaluate the effect of pre-heating of bulk -fill resin composites on monomer elution from them. Material and Methods: Three different types of resin composites were used including Tetric N-Ceram Bulk Fill, X-tra Fill and X-tra Base. 10 cylindrical samples were prepared from each resin composites. Before light curing, 5 samples were pre-heated until reaching 68˚C, then 5 other samples were polymerized at room temperature. After 24 hours, release of UDMA, TEGDMA and BIS-GMA monomers were measured by High-Performance Liquid Chromatography analysis. Data analysis was performed by two-way ANOVA test, Games-Howell and Sidak post hoc tests. Results: Pre-heating did not have any statistically significant effect on the mean values of UDMA, TEGDMA and Bis-GMA elution (p>0.05). The greatest amount of released Bis-GMA and UDMA was obtained from Tetric N-Ceram Bulk-fill composite. The greatest amount of released TEGDMA was obtained from X-tra Fill composite. X-tra Base composite showed the lowest amount of monomer release (P<0.001). Conclusions: Pre-heating did not have any effect on monomer release from bulk-fill resin composites. Moreover, the amount and the type of monomers released from various bulk-fill resin composites were not similar.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
محمد اسماعیل ابراهیمی چهارماول
المیرا جعفری نویمی پورچهارم
پرنیان علیزاده اسکوییپنجم
امیر احمد عجمیششم
مهدی عابد کهنموییهفتم
محمود بهاریهشتم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
The effect of pre-heating on monomer elution from bulk-fill resin composites.pdf1399/06/30751576دانلود