Development of a reliable bioanalytical method based on prostate specific antigen trapping on the cavity of molecular imprinted polymer towards sensing of PSA using binding affinity of PSA-MIP receptor: A novel biosensor

Development of a reliable bioanalytical method based on prostate specific antigen trapping on the cavity of molecular imprinted polymer towards sensing of PSA using binding affinity of PSA-MIP receptor: A novel biosensor


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: لیلا عباسی , آرزو محمد زاده , محمد حسن زاده محله

کلمات کلیدی: Biomedical analysis, Biomacromolecules, Binding affinity, Biosensor, Encapsulation. Prostate cancer

نشریه: 18344 , 01 , 188 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمد حسن زاده محله
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات آنالیز دارویی
کد مقاله 73112
عنوان فارسی مقاله Development of a reliable bioanalytical method based on prostate specific antigen trapping on the cavity of molecular imprinted polymer towards sensing of PSA using binding affinity of PSA-MIP receptor: A novel biosensor
عنوان لاتین مقاله Development of a reliable bioanalytical method based on prostate specific antigen trapping on the cavity of molecular imprinted polymer towards sensing of PSA using binding affinity of PSA-MIP receptor: A novel biosensor
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

In this study, electrically-conducting poly [Toluidine Blue (PTB)] was applied as artificial receptor. It was organized by molecular imprinting approaches and via electrochemical technique for the sensitive monitoring of prostate-specific antigen (PSA). The protein-imprinted PTB was electropolymerized in a pre-formed glutaraldehyde-cysteamine (GA-Cys A) matrix on the surface of gold electrode, which significantly boosted the stability against degradation of the Molecular Imprinted Polymer (MIP) on the surface of pre-modified gold electrode. Moreover, the MIP bio-receptor ability towards protein recognition was explored by some electrochemical techniques. The binding affinity of MIP system was considerably upper than that of non-imprinted polymer (NIP) system, indicating the success of the method in generating imprinted materials that was specifically use to PSA protein. The incubation of the MIP modified electrode in various concentration of PSA (from 1–60 μg/L) resulted in the increase of the Fe (CN)6 3−/4− redox peak current. The bio-device also showed linear response from 1–60 μg/L and LLOQ of 1 μg/L by using DPV technique, leading to PSA monitoring in clinical samples. The proposed MIP-based biosensor was satisfactorily applied to the determination of PSA in human plasma samples. Therefore, the developed bio-device provides a new approach for sensitive, simple, rapid, and cost-effective monitoring of 1 μg/L of PSA. Notably, this approach could appear as an appropriate candidate for point-of-care (POC) use in clinical and biomedical analyses.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
لیلا عباسیاول
آرزو محمد زادهاول
محمد حسن زاده محلهسوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
1.pdf1399/05/141617607دانلود