Utilizing a Nanocomposite Based on Ion-Imprinted Polydopamine-Coated Magnetic Graphene Oxide for Extraction of Cd(II) and Ni(II) from Water Samples

Utilizing a Nanocomposite Based on Ion-Imprinted Polydopamine-Coated Magnetic Graphene Oxide for Extraction of Cd(II) and Ni(II) from Water Samples


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: الهه رحیم پور

کلمات کلیدی: cadmium, nickel, graphene oxide, ion-imprinted polymer, magnetic solid phase extraction

نشریه: 55279 , 8 , 75 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله الهه رحیم پور
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات آنالیز دارویی
کد مقاله 73077
عنوان فارسی مقاله Utilizing a Nanocomposite Based on Ion-Imprinted Polydopamine-Coated Magnetic Graphene Oxide for Extraction of Cd(II) and Ni(II) from Water Samples
عنوان لاتین مقاله Utilizing a Nanocomposite Based on Ion-Imprinted Polydopamine-Coated Magnetic Graphene Oxide for Extraction of Cd(II) and Ni(II) from Water Samples
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

In this study, a new magnetic ion-imprinted polymer was prepared as a nanosorbent for selective extraction and pre-concentration of low levels of Cd(II) and Ni(II) prior to determination by flame atomic absorption spectrometry. The sorbent material consists of graphene oxide as a carrier, Fe3O4 nanoparticles as magnetic components immobilized on the surface of the carrier and polydopamine as a metal ion-imprinted polymer which is uniformly coated on the surface of the magnetic graphene oxide sheet layer. Several factors affecting the extraction of the analytes were studied and optimized. In the optimum conditions, the calibra- tion graphs were linear in the ranges of 0.1–18 and 0.1–20 ng/mL for Cd(II) and Ni(II), respectively. The limits of detection (3sb/m) for Cd(II) and Ni(II) were 25 and 60 pg/mL, respectively. The accuracy of the method was confirmed by successful analyzing the certified reference material NIST SRM 1643e. The method can be used for the pre-concentration and determination of Ni(II) and Cd(II) in water samples.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
الهه رحیم پوردوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Utilizing a Nanocomposite Based on Ion Imprinted PolydopamineCoated Magnetic Graphene Oxide (1).pdf1399/05/12855983دانلود