In-process prepared deep eutectic solvent based homogeneous liquid–liquid microextraction for the determination of irgaphos 168 and irganox 1010 in polypropylene packed drinks
In-process prepared deep eutectic solvent based homogeneous liquid–liquid microextraction for the determination of irgaphos 168 and irganox 1010 in polypropylene packed drinks
نویسندگان: محمدرضا افشار مقدم , مریم نائبی
کلمات کلیدی: deep eutectic solvents, homogeneous liquid–liquid microextraction, irganox 1010, irgaphos 168, polypropylene
package
نشریه: 55358 , 14 , 43 , 2020
| نویسنده ثبت کننده مقاله |
محمدرضا افشار مقدم |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات ایمنی غذا و دارو |
| کد مقاله |
73038 |
| عنوان فارسی مقاله |
In-process prepared deep eutectic solvent based homogeneous liquid–liquid microextraction for the determination of irgaphos 168 and irganox 1010 in polypropylene packed drinks |
| عنوان لاتین مقاله |
In-process prepared deep eutectic solvent based homogeneous liquid–liquid microextraction for the determination of irgaphos 168 and irganox 1010 in polypropylene packed drinks |
| ناشر |
5 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
خیر |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| In situ synthesis of a deep eutectic solvent and homogeneous liquid–liquid microextraction
performed in a narrow bore tube was developed for efficient extraction of
irgaphos 168 and irganox 1010 in doogh and water samples packed in polypropylene
packages. First, pH of the aqueous sample solutions containing the analytes is
adjusted at 9. Then a hydrogen bond acceptor (choline chloride) and a hydrogen bond
donor (oleic acid) are dissolved in the solution and vortexed to obtain a homogeneous
solution. The solution is filled into a narrow bore tube, in which its bottom was
clogged by a septum. Then hydrochloric acid solution is injected into the solution by
a syringe. The tube is placed in an ultrasonic bath. During this step, the droplets of
choline chloride:oleic acid deep eutectic solvent are produced. The method indicated
high enrichment factor (435 for irgaphos 168 and 488 for irganox 1010), low limits
of detection (0.03 and 0.09 ng/mL for irgaphos 168 and irganox 1010, respectively)
and quantification (0.13 and 0.29 ng/mL for irgaphos 168 and irganox 1010), good
recovery (74 and 83% for irgaphos 168 and irganox 1010, respectively), and satisfactory
repeatabilities (relative standard deviations ≤12%) can be obtained using the
developed method. |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| JSS-Jamshidi-Abolhassani.pdf | 1399/05/09 | 1182665 | دانلود |