کامپوزیت نانوگرافن اکسید عامل دار شده با سیلیکا بعنوان یک جاذب استخراجی فاز جامد موثر برای استخراج متیل فنیدات از نمونه های ادراری
Silica functionallized nano-graphene oxide composite as potent-dispersive solid phase extraction addorbent of methylphenidate from urine sample
نویسندگان: شادی جاهداورنگ , ارزو تقویمی , یوسف جوادزاده
کلمات کلیدی: Silica-functionalized nano-graphene oxide composite
Methylphenidate
Urine
Solid-phase extraction
HPLC
نشریه: 2955 , 1 , 45 , 2020
| نویسنده ثبت کننده مقاله |
یوسف جوادزاده |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
دانشکده داروسازی |
| کد مقاله |
72492 |
| عنوان فارسی مقاله |
کامپوزیت نانوگرافن اکسید عامل دار شده با سیلیکا بعنوان یک جاذب استخراجی فاز جامد موثر برای استخراج متیل فنیدات از نمونه های ادراری |
| عنوان لاتین مقاله |
Silica functionallized nano-graphene oxide composite as potent-dispersive solid phase extraction addorbent of methylphenidate from urine sample |
| ناشر |
4 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| Silica-functionalized nano-graphene oxide composite (SFNGC) was successfully synthesized by a simple and cost-effective method. The resulted material was characterized and used as dispersive solid-phase extraction (DSPE) adsorbent for selective extraction of methylphenidate from urine media coupled with high-performance liquid chromatography ultra-violet detector. The DSPE adsorbent was dispersed thoroughly in the media through hydrophilic functional groups on the surface and could interact well by methylphenidate according to electrostatic reaction. Factors affecting the extraction process were studied by one-parameter-at-a-time method. The summery of the optimized parameters is as follows: 400 µL of methanol, urine pH value of 9, 60 mg of SFNGC, 4000 stirring rate, 20 min of extraction period and 25 min of desorption time and 6 mL of urine volume were the optimized as extraction parameters. By profiling the calibration curve, the linear range of the method was regarded as 100–2000 ng/mL. Limit of detection for the new method was 30 ng/mL. The analysis of addicted subjects with the proposed method confirmed the capability of the method in different laboratories. |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| Shadi Jahed-methylphenidate.pdf | 1399/03/21 | 1130008 | دانلود |