Efficacy of Microwave Disinfection on Moist and Dry Dental Stone Casts with Different Irradiation Times
Efficacy of Microwave Disinfection on Moist and Dry Dental Stone Casts with Different Irradiation Times
نویسندگان: محمود رباطی انارکی , محمد تقی اخی , الناز مصلحی فرد , طاهره پیرزاده , سید امین موسوی قاضی کندی , آذین خرمدل
کلمات کلیدی: Microwave Disinfection; Dental Stone Casts; Irradiation Times
نشریه: 0 , 3 , 3 , 2015
| نویسنده ثبت کننده مقاله |
محمود رباطی انارکی |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
دانشکده دندانپزشکی |
| کد مقاله |
72349 |
| عنوان فارسی مقاله |
Efficacy of Microwave Disinfection on Moist and Dry Dental Stone Casts with Different Irradiation Times |
| عنوان لاتین مقاله |
Efficacy of Microwave Disinfection on Moist and Dry Dental Stone Casts with Different Irradiation Times |
| ناشر |
7 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
Advances in Bioscience & Clinical Medicine |
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح چهار – سایر سایت های تخصصی |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| Objectives: Dental practice contains the use of instruments and multiuse items that should be sterilized
or disinfected properly. The aim of the current study was to investigate the effect of microwave
irradiation on dental stone cast disinfection in moist and dry condition.
Materials and Methods: In this in vitro study, 76 stone casts were prepared by a sterile method. The
casts were contaminated by Pseudomonas aeruginosa (ATCC 9027), Staphylococcus aureus (ATCC 6538),
Enterococcus faecalis (ATCC 29212) as well as Candida albicans (ATCC 10231). Half the samples were
dried for two hours and the other half was studied while still moist. The samples were irradiated by a
household microwave at 600 W for 3, 5 and 7 minutes. The microorganisms on the samples were
extracted by immersion in tryptic soy broth and .001 ml of that was cultured in nutrient agar media,
incubated overnight and counted and recorded as colony forming unit per milliliter (CFU/mL).
Results: The findings showed that microorganisms reduced to 4.87 logarithm of CFU/mL value on dental
cast within seven minutes in comparison with positive control. Although microbial count reduction was
observed as a result of exposure time increase, comparison between moist and dried samples showed
no significant difference.
Conclusions: Seven-minute microwave irradiation at 600 W can effectively reduce the microbial load of
dental stone casts. Wetting the casts does not seem to alter the efficacy of irradiation. |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| moist moosavi.pdf | 1399/03/06 | 626253 | دانلود |