Anatomical variations of maxillary sinus: a cone-beam computed tomography study

Anatomical variations of maxillary sinus: a cone-beam computed tomography study


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: علی تراب , جواد یزدانی , فریدون پرنیا

کلمات کلیدی: Sinus anatomy; Anatomical variations; Septum; Cyst

نشریه: 0 , 3 , 8 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله فریدون پرنیا
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 71571
عنوان فارسی مقاله Anatomical variations of maxillary sinus: a cone-beam computed tomography study
عنوان لاتین مقاله Anatomical variations of maxillary sinus: a cone-beam computed tomography study
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) Biointerface Research in Applied Chemistry
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

The goal of current project was to evaluate the maxillary sinus dimensions using cone-beam computed tomography (CBCT) to assess anatomical variations. A total of 86 CBCT examinations were retrospectively performed in this regard. In this study, the Promax 3D CBCT unit was used for the dimension determination in para-axial, occlusal and panoramic views. In para-axial view, sinus height and width were 31.7 mm and 23.2 mm, in panoramic view (frontal plan) 29.9mm and 27.9 respectively and in occlusal view mean sinus length and width were 33.9 mm and 23.1 mm respectively. The dome-shaped maxillary sinus cyst was observed in 27% of patients. Sinus septum was determined in 29 % of patients (the mean height =8.1 mm). Other results were included the distances from the anterior wall of maxillary sinus to the midline mean distance (31.4 mm, SD= 8.3) and the mean distance from the lower border of the maxillary sinus to the alveolar crest of the maxilla (11.0 mm, SD= 4.4). Anatomical variations of maxillary sinus can change some vital surgery planning. The cone-beam computed tomography (CBCT) can be applied for an accurate assessment and additional validation of maxillary septum existence and avoid unnecessary surgical examinations.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
علی ترابسوم
جواد یزدانیاول
فریدون پرنیادوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
4_5845866500388291626.pdf1399/01/17636424دانلود