Ferrofluid-based dispersive liquid–liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats

Ferrofluid-based dispersive liquid–liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: ابوالقاسم جویبان , محمدرضا افشار مقدم , محبوب نعمتی , علی اکبر علیزاده نبیل

کلمات کلیدی: Ferrofluid, Dispersive liquid–liquid microextraction, Deep eutectic solvent, Polycyclic aromatic hydrocarbons, Grilled meat samples, Gas chromatography–mass spectrometry

نشریه: 1985 , 1 , 12 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمدرضا افشار مقدم
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات ایمنی غذا و دارو
کد مقاله 71553
عنوان فارسی مقاله Ferrofluid-based dispersive liquid–liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats
عنوان لاتین مقاله Ferrofluid-based dispersive liquid–liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

An ultrasonic-assisted ferrofluid-based dispersive liquid–liquid microextraction procedure combined with microwave-assisted counter current extraction has been used for the extraction of sixteen polycyclic aromatic hydrocarbons from grilled meat samples. In this method, a mixture of acetonitrile and sodium hydroxide solutions was added to the sample and the mixture was exposed to microwave radiation. Then, the mixture was passed through a barrel filled with sodium sulfate and the separated acetonitrile was mixed with an Fe3O4@TEOS–phosphocholine : menthol : decanoic acid ferrofluid. The mixture was rapidly dispersed in a sodium chloride solution (4%, w/v) and sonicated. The ferrofluid was discarded from the solution by an external magnet. Finally, the analytes were extracted into n-hexane and determined by gas chromatography-mass spectrometry. The validation parameters showed that the method has low limits of detection (in the range of 29–82 ng kg1) and quantification (in the range of 97–277 ng kg1), good extraction recoveries (73–92%), and high enrichment factors (730–920). Relative standard deviations less than 10% were obtained for intra- (n ¼ 6) and inter-day (n ¼ 6) precisions. Finally, 10 different grilled meat samples were successfully analyzed and fluoranthene, pyrene, and fluorene were found in most samples

نویسندگان
hide/show

نویسنده نفر چندم مقاله
ابوالقاسم جویباناول
محمدرضا افشار مقدمسوم
محبوب نعمتیچهارم
علی اکبر علیزاده نبیلپنجم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Analytical methods-Ferrofluid.pdf1399/01/15642115دانلود