Ferrofluid-based dispersive liquid–liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats
Ferrofluid-based dispersive liquid–liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats
نویسندگان: ابوالقاسم جویبان , محمدرضا افشار مقدم , محبوب نعمتی , علی اکبر علیزاده نبیل
کلمات کلیدی: Ferrofluid, Dispersive liquid–liquid microextraction, Deep eutectic solvent, Polycyclic aromatic hydrocarbons, Grilled meat samples, Gas chromatography–mass spectrometry
نشریه: 1985 , 1 , 12 , 2020
| نویسنده ثبت کننده مقاله |
محمدرضا افشار مقدم |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات ایمنی غذا و دارو |
| کد مقاله |
71553 |
| عنوان فارسی مقاله |
Ferrofluid-based dispersive liquid–liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats |
| عنوان لاتین مقاله |
Ferrofluid-based dispersive liquid–liquid microextraction using a deep eutectic solvent as a support: applications in the analysis of polycyclic aromatic hydrocarbons in grilled meats |
| ناشر |
5 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| An ultrasonic-assisted ferrofluid-based dispersive liquid–liquid microextraction procedure combined with
microwave-assisted counter current extraction has been used for the extraction of sixteen polycyclic
aromatic hydrocarbons from grilled meat samples. In this method, a mixture of acetonitrile and sodium
hydroxide solutions was added to the sample and the mixture was exposed to microwave radiation.
Then, the mixture was passed through a barrel filled with sodium sulfate and the separated acetonitrile
was mixed with an Fe3O4@TEOS–phosphocholine : menthol : decanoic acid ferrofluid. The mixture was
rapidly dispersed in a sodium chloride solution (4%, w/v) and sonicated. The ferrofluid was discarded
from the solution by an external magnet. Finally, the analytes were extracted into n-hexane and
determined by gas chromatography-mass spectrometry. The validation parameters showed that the
method has low limits of detection (in the range of 29–82 ng kg1) and quantification (in the range of
97–277 ng kg1), good extraction recoveries (73–92%), and high enrichment factors (730–920). Relative
standard deviations less than 10% were obtained for intra- (n ¼ 6) and inter-day (n ¼ 6) precisions.
Finally, 10 different grilled meat samples were successfully analyzed and fluoranthene, pyrene, and
fluorene were found in most samples |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| Analytical methods-Ferrofluid.pdf | 1399/01/15 | 642115 | دانلود |