easuring the dose–width product and proposing the local diagnostic reference level in panoramic dental radiography: a multi‑center study from Iran

Measuring the dose–width product and proposing the local diagnostic reference level in panoramic dental radiography: a multi‑center study from Iran


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: داود خضرلو , توحید مرتضی زاده

کلمات کلیدی: Panoramic radiography · Dose–width product (DWP) · Diagnostic reference level (DRL) · Iran

نشریه: 26303 , 77 , 36 , 2020

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله داود خضرلو
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده پیراپزشکی
کد مقاله 71289
عنوان فارسی مقاله easuring the dose–width product and proposing the local diagnostic reference level in panoramic dental radiography: a multi‑center study from Iran
عنوان لاتین مقاله Measuring the dose–width product and proposing the local diagnostic reference level in panoramic dental radiography: a multi‑center study from Iran
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract Objective Although radiation exposure associated with dental radiography is relatively low, patient exposure must be kept practically low. Therefore, it is necessary for each country to establish its own diagnostic reference levels (DRLs) suitable for its equipment and practice. In the present study, dose-width product (DWP) values for panoramic dental radiography were measured and a local DRL was established. Methods Five panoramic devices from fve radiology clinics of Kashan, Iran were selected to measure the DWP values of panoramic dental radiography. To investigate the DWP values, the parameters of each patient’s exposure (e.g., tube voltage, tube current, and exposure time) at these fve radiology clinics were extracted. Then, the dose value received by each patient was measured based on a CT pencil chamber. Finally, the overall median DWP values for the patients with small, medium, and large sizes were obtained, and these values were considered as the local DRLs for panoramic dental radiography. Results A total of 99 adult patients were included in the present study. The fndings demonstrated that the median and thirdquartile DWP values for these fve radiology clinics ranged from 42.3 to 94.3 and 49.7 to 142.8 mGy mm, respectively. The local DRL values, which were established as the overall median DWP values, were 43.4, 52.0, and 80.3 mGy mm for the adults with small, medium, and large sizes, respectively. Conclusion The local DRL proposed in this study for the adult with standard/medium size was lower than those proposed by other reports and seemed acceptable for panoramic radiography in Kashan, Iran.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
داود خضرلودوم
توحید مرتضی زادهششم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Article_MeasuringTheDoseWidthProductAn.pdf1399/05/26624274دانلود