Developing a high-performance liquid chromatography fast and accurate method for quantifcation of silibinin

Developing a high-performance liquid chromatography fast and accurate method for quantifcation of silibinin


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: فائزه بخشی , ام لیلا مولوی , محمدرضا رشیدی شاهگلی , علی شایان فر , حسن امینی

کلمات کلیدی: KEYWORDS: Analysis method; HPLC; Method validation; Precision and accuracy; Silibinin

نشریه: 55078 , 743 , 12 , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله حسن امینی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز سلولهای بنیادی
کد مقاله 70793
عنوان فارسی مقاله Developing a high-performance liquid chromatography fast and accurate method for quantifcation of silibinin
عنوان لاتین مقاله Developing a high-performance liquid chromatography fast and accurate method for quantifcation of silibinin
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract OBJECTIVE: Silibinin is an antioxidant agent and is shown to have anticancer effects in different cancers including lung, breast, colorectal, liver, prostate, and kidney. There are challenges in the clinical use of silibinin. The main limitation is low solubility, poor oral absorption, and extensive hepatic metabolism. We aim to develop a High-Performance Liquid Chromatography (HPLC) sensitive method for quantification of silibinin in aqueous samples to quantify its concentration in new formulations. A reverse-phase high-performance liquid chromatography (RP-HPLC) composed of C18 column as stationary phase and the mixture of methanol (90%) and water (10%) as mobile phase. The developed method was validated based on the established guidelines. RESULTS: The retention time for silibinin was seen in 2.97 min after injection. The calibration curve was drawn and the established method demonstrated a linear ranged from 10 to 100 µg/ml, with a correlation coefficient of 0.996. The sensitivity of the developed method was 10 µg/ml. The accuracy calculated in the range of 88-105.9% and the precision (as relative standard deviation) was between 2.7 and 10.9%. These results demonstrate that the developed method can be a fast and accurate method for quantification of silibinin in aqueous samples.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
فائزه بخشیاول
ام لیلا مولویدوم
محمدرضا رشیدی شاهگلیسوم
علی شایان فرچهارم
حسن امینیپنجم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
2019 Developing a high-performance liquid chromatography fast and accurate method for quantifcation of silibinin.pdf1398/10/24848392دانلود