Magnetic nano‑carbon core shell as potent mixed hemimicelle solid phase extraction strategy for determination of acrylamide from potato chips coupled by high‑performance liquid chromatography

Magnetic nano‑carbon core shell as potent mixed hemimicelle solid phase extraction strategy for determination of acrylamide from potato chips coupled by high‑performance liquid chromatography


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: مهناز طبیبی اذر , ارزو تقویمی , سیاوش دستمالچی , ثمین حمیدی , یوسف جوادزاده

کلمات کلیدی: Magnetic solid phase extraction · Mixed hemimicelle · Magnetic nano-carbon core shell · Potato chips · Acrylamide · HPLC–UV

نشریه: 21870 , 2019 , 2019 , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله مهناز طبیبی اذر
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده تغذیه
کد مقاله 70635
عنوان فارسی مقاله Magnetic nano‑carbon core shell as potent mixed hemimicelle solid phase extraction strategy for determination of acrylamide from potato chips coupled by high‑performance liquid chromatography
عنوان لاتین مقاله Magnetic nano‑carbon core shell as potent mixed hemimicelle solid phase extraction strategy for determination of acrylamide from potato chips coupled by high‑performance liquid chromatography
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Magnetic nano-carbon core shell was applied as mixed hemimicelle magnetic solid phase extraction adsorbent to introduce a novel sample preparation method for determination of acrylamide from potato chips. Acrylamide is identified as neurotoxic, a probable human carcinogen (group 2A) compound. Effective extraction parameters such as type and amount of extracting solvent, type and amount of adsorbent, time of extraction and desorption, the effect of pH, time of ionic liquid loading on the adsorbent and stirring rate (rpm) were studied and optimized. Under optimized extraction conditions, a good linearity was observed in the concentration range of 100–1500 ng/g. Limit of detection was observed as 30 ng/g. Application of the proposed method was surveyed by analysis of some potato chips brands available in the local supermarkets. The satisfactory results with the recovery of 95.58% revealed that the proposed method could be applied in food analysis laboratories.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
مهناز طبیبی اذرپنجم
ارزو تقویمیاول
سیاوش دستمالچیچهارم
ثمین حمیدیدوم
یوسف جوادزادهسوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Taghvimi2019_Article_MagneticNano-carbonCoreShellAs.pdf1398/10/24983959دانلود