Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study

Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: الناز مصلحی فرد

کلمات کلیدی: Corrosion, EIS, Polarization, Dental materials, Ion release, Ni-Cr-Mo, Nickel, Passive films, SEM

نشریه: 2669 , 6 , 66 , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله الناز مصلحی فرد
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 70363
عنوان فارسی مقاله Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study
عنوان لاتین مقاله Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract Purpose – The purpose of this paper (in vitro) study was to determine the effect of pH of artificial saliva on the corrosion behavior of a Ni-Cr-Mo alloy at 37 6 1°C. Design/methodology/approach – The corrosion behavior of a commercially available Ni-Cr-Mo base dental alloy was studied by potentiodynamic polarization and electrochemical impedance spectroscopy techniques. The effect of pH on corrosion and Ni ion release was also investigated by scanning electron microscopy and atomic absorption spectroscopy. Findings – The results suggested that the order of corrosion rate was: pH3 > pH5 > pH9 > pH7. Corrosion rate in pH3 was significantly different with other pH levels. Nickel depletion significantly occurred in alloy without passivation. The corrosion resistance and ion release of Ni-Cr-Mo alloys in different pH levels of artificial saliva depended on the stability of the passive layer. Acidic pH level severely corrodes Ni-Cr-Mo base metal alloys and increases Ni ion release. Originality/value – This manuscript describes the relationship between corrosion rate and nickel ion release of a dental Ni-Cr-Mo base alloy as a function of saliva pH examined by electrochemical impedance spectroscopy (EIS), polarization, scanning electron microscopy and energy dispersive X-ray spectroscopy in artificial saliva. The main novelty of this work includes the material/structure/corrosion relationship in artificial saliva with different pH. This property would be very interesting for dental materials applications and clinical dentistry. Keywords Corrosion, EIS, Polarization, Dental materials, Ion release, Ni-Cr-Mo, Nickel, Passive films, SEM

نویسندگان
hide/show

نویسنده نفر چندم مقاله
الناز مصلحی فرداول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
corrosio.pdf1398/09/205258767دانلود