Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study
Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study
نویسندگان: الناز مصلحی فرد
کلمات کلیدی: Corrosion, EIS, Polarization, Dental materials, Ion release, Ni-Cr-Mo, Nickel, Passive films, SEM
نشریه: 2669 , 6 , 66 , 2019
| نویسنده ثبت کننده مقاله |
الناز مصلحی فرد |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
دانشکده دندانپزشکی |
| کد مقاله |
70363 |
| عنوان فارسی مقاله |
Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study |
| عنوان لاتین مقاله |
Influence of pH level of artificial saliva on corrosion behavior and nickel ion release of a Ni-Cr-Mo alloy: an in vitro study |
| ناشر |
3 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
خیر |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| Abstract
Purpose – The purpose of this paper (in vitro) study was to determine the effect of pH of artificial saliva on the corrosion behavior of a Ni-Cr-Mo
alloy at 37 6 1°C.
Design/methodology/approach – The corrosion behavior of a commercially available Ni-Cr-Mo base dental alloy was studied by potentiodynamic
polarization and electrochemical impedance spectroscopy techniques. The effect of pH on corrosion and Ni ion release was also investigated by
scanning electron microscopy and atomic absorption spectroscopy.
Findings – The results suggested that the order of corrosion rate was: pH3 > pH5 > pH9 > pH7. Corrosion rate in pH3 was significantly different
with other pH levels. Nickel depletion significantly occurred in alloy without passivation. The corrosion resistance and ion release of Ni-Cr-Mo alloys
in different pH levels of artificial saliva depended on the stability of the passive layer. Acidic pH level severely corrodes Ni-Cr-Mo base metal alloys
and increases Ni ion release.
Originality/value – This manuscript describes the relationship between corrosion rate and nickel ion release of a dental Ni-Cr-Mo base alloy as a
function of saliva pH examined by electrochemical impedance spectroscopy (EIS), polarization, scanning electron microscopy and energy dispersive
X-ray spectroscopy in artificial saliva. The main novelty of this work includes the material/structure/corrosion relationship in artificial saliva with
different pH. This property would be very interesting for dental materials applications and clinical dentistry.