Relation between Coronary Sinus O2 Saturation and Response to Cardiac Resynchronization Therapy in Patients with Severe Heart Failure

Relation between Coronary Sinus O2 Saturation and Response to Cardiac Resynchronization Therapy in Patients with Severe Heart Failure


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: فریبرز اکبرزاده , مهرنوش طوفان تبریزی , بابک کاظمی اربط

کلمات کلیدی: Cardiac synchronization therapy, Coronary sinus O2 Saturation, Congestive heart failure

نشریه: 36322 , 5 , 35 , 2013

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله بابک کاظمی اربط
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات قلب وعروق
کد مقاله 70065
عنوان فارسی مقاله Relation between Coronary Sinus O2 Saturation and Response to Cardiac Resynchronization Therapy in Patients with Severe Heart Failure
عنوان لاتین مقاله Relation between Coronary Sinus O2 Saturation and Response to Cardiac Resynchronization Therapy in Patients with Severe Heart Failure
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح چهار – سایر سایت های تخصصی
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Backgrounds and Objectives: Congestive Heart Failure (CHF) is a prevalent disease and has a great economic impact on health systems. Cardiac Resynchronization Therapy (CRT), which synchronize biventricular contraction, is one of the most important therapies in these patients. Despite the exact selection of patients about 30% of patients do not respond to CRT. The aim of this study was to evaluate the O2 saturation and the pressure level of right side of heart and Coronary Sinus (CS) vein to predict the response to CRT. Materials and Methods: In this descriptive study, 30 patients were candidate for implantation of CRT echocardiography. The 6 Minute Walk Test (6MW), right side and CS O2 saturation and pressure study was done before implantation. Echocardiography and 6MW repeated 6 months later. Based on response to the CRT, patients were divided into two groups: “responder and non-responder”. Date were compared between groups. Results: O2 saturation was significantly lower in responders than non-responders. In non-responder patients the Right Ventricular (RV) and Pulmonary Artery (PA) Pressure was significantly higher than responders. Desaturation of CS blood flow in responders was probably due to higher levels of viable tissue which involve in contraction. Increase in right side and PA pressure in non-responders might be due to severity of heart failure which made CRT not effective in these patients. Conclusion: Evaluation of O2 saturation of CS blood flow, RV and PA pressure can use as an index in predicting the response to CRT and can help as additional indices in selection of patients with borderline indications for implanting CRT.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
فریبرز اکبرزادهاول
مهرنوش طوفان تبریزیدوم
بابک کاظمی اربطسوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
Relation between Coronary Sinus O2 Saturation and Response to Cardiac Resynchronization.pdf1398/09/13631187دانلود