The Comparison of Stress Distribution with Different Implant Numbers and Inclination Angles In All-on-four and Conventional Methods in Maxilla: A Finite Element Analysis

The Comparison of Stress Distribution with Different Implant Numbers and Inclination Angles In All-on-four and Conventional Methods in Maxilla: A Finite Element Analysis


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: فریبا صالح صابر , شیما قاسمی , رودابه کودریان , امیر رضا بابالو , نادر ابوالفضلی

کلمات کلیدی: Dental implant, finite element analysis, maxilla

نشریه: 19913 , 4 , 9 , 2015

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله شیما قاسمی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 69406
عنوان فارسی مقاله The Comparison of Stress Distribution with Different Implant Numbers and Inclination Angles In All-on-four and Conventional Methods in Maxilla: A Finite Element Analysis
عنوان لاتین مقاله The Comparison of Stress Distribution with Different Implant Numbers and Inclination Angles In All-on-four and Conventional Methods in Maxilla: A Finite Element Analysis
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract Background and aims. All-on-four technique involves the use of tilted implants to allow for shorter cantilevers. This finite element analysis aimed at investigating the amount and distribution of stress in maxillary bone surrounding the implants with all-on-four vs. frequently used method with six implants technique using different numbers and inclination angles. Materials and methods. A 3D edentulous maxillary model was created and implants were virtually placed anterior to the maxillary sinus and splinted with a superstructure. In total, five models were designed. In the first to the fourth models, four implants were placed with distal implants inclined 0, 15, 30, and 45 degrees, respectively. In the fifth model, six vertical implants were placed. 100 N loading was placed in the left most distal region of the superstructure. Maximum von Mises stress values were evaluated in cancellous and cortical bone. Results. The maximum stress values recorded in cancellous and cortical bone were 7.15 MPa and 51.69 MPa, respectively (model I). The reduction in stress values in models II to V 6%, 18%, 54%, and 24% in cancellous bone and 12%, 36%, 62%, and 62% in cortical bone, respectively. Conclusion. Increasing the inclination in posterior implants resulted in reduction of cantilever length and maximum stress decline in both cancellous and cortical bone. The effect of cantilever length seems to be a dominant factor which can diminish stress even with less number of implants.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
فریبا صالح صابراول
شیما قاسمیدوم
رودابه کودریانسوم
امیر رضا بابالوچهارم
نادر ابوالفضلیپنجم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
1-all on 4.pdf1398/07/27369597دانلود