Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry

Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: اصغر مصباحی , ناهیده قره آغاجی

کلمات کلیدی: Gel dosimetry Optical absorbance Polymer gel

نشریه: 0 , 17 , 3 , 2012

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله ناهیده قره آغاجی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده پیراپزشکی
کد مقاله 69132
عنوان فارسی مقاله Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry
عنوان لاتین مقاله Optical and NMR dose response of N-isopropylacrylamide normoxic polymer gel for radiation therapy dosimetry
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) Reports of practical oncology and radiotherapy
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Background: Application of less toxic normoxic polymer gel of N-isopropyl acrylamide (NIPAM) for radiation therapy has been studied in recent years. Aim: In the current study the optical andNMRproperties of NIPAMwere studied for radiation therapy dosimetry application. Materials and methods: NIPAM normoxic polymer gel was prepared and irradiated by 9MV photon beam of a medical linac. The optical absorbance was measured using a conventional laboratory spectrophotometer in different wavelengths ranging from 390 to 860 nm. R2 measurements of NIPAM gels were performed using a 1.5T scanner and R2–dose curve was obtained. Results: Our results showed R2 dose sensitivity of 0.193±0.01 s−1 Gy−1 for NIPAM gel. Both R2 and optical absorbance showed a linear relationship with dose from 1.5 to 11 Gy for NIPAM gel dosimeter. Moreover, absorbance–dose response varied considerably with light wavelength and highest sensitivity was seen for the blue part of the spectrum. Conclusion: Our results showed that both optical and NMR approaches have acceptable sensitivity and accuracy for dose determination with NIPAM gel. However, for optical reading of the gel, utilization of an optimum optical wavelength is recommended.