Sensitivity of Palm Print, Modified Mallampati Score and 3‑3‑2 Rule in Prediction of Difficult Intubation

Sensitivity of Palm Print, Modified Mallampati Score and 3‑3‑2 Rule in Prediction of Difficult Intubation


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: عطا محمودپور , حسن سلیمانپور , کاووس شهسواری نیا , جعفر رحیمی پناهی , محمدرضا افهمی , صمد اسلام جمال گلزاری

کلمات کلیدی: Difficult intubation, modified Mallampati score, palm print, 3‑3‑2 rule

نشریه: 16117 , 9 , 4 , 2013

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله صمد اسلام جمال گلزاری
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه طب فیزیکی وتوانبخشی
کد مقاله 69084
عنوان فارسی مقاله Sensitivity of Palm Print, Modified Mallampati Score and 3‑3‑2 Rule in Prediction of Difficult Intubation
عنوان لاتین مقاله Sensitivity of Palm Print, Modified Mallampati Score and 3‑3‑2 Rule in Prediction of Difficult Intubation
ناشر 7
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح سه – Scopus
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Methods: In a prospective descriptive study, data from 500 patients scheduled for elective surgery under general anesthesia were collected. An anesthesiologist evaluated the airway using mentioned tests and another anesthesiologist evaluated difficult intubation. Laryngoscopic views were determined by Cormack and Lehane score. Grades 3 and 4 were defined as difficult intubation. Sensitivity, specificity, positive predictive value, negative predictive value and Youden index were determined for all tests. Results: Difficult intubation was reported in 8.9% of the patients. There was a significant correlation between body mass index and difficult intubation (P : 0.004); however, other demographic characteristics didn’t have a significant correlation with difficult intubation. Among three tests, palm print was of highest specificity (96.46%) and modified Mallampati of highest sensitivity (98.40%). In a combination of the tests, the highest specificity, sensitivity and Youden index were observed when using all three tests together. Conclusions: Palm print has a high specificity for prediction of difficult intubation, but the best way for prediction of difficult intubation is using all three tests together.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
عطا محمودپوراول
حسن سلیمانپوردوم
کاووس شهسواری نیاسوم
جعفر رحیمی پناهیچهارم
محمدرضا افهمیپنجم
صمد اسلام جمال گلزاریششم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
O-Palm print.pdf1398/07/06926838دانلود