Evaluation of cortical bone thickness of mandible with cone beam computed tomography for orthodontic mini implant installation

Evaluation of cortical bone thickness of mandible with cone beam computed tomography for orthodontic mini implant installation


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: امین نوری زاده , سید حسین مسلم زاده , آیدین سهرابی , یوسف کنعانی زاده

کلمات کلیدی: Cone-beam computed tomography; orthodontic anchorage procedures

نشریه: 0 , 2 , 2 , 2014

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله امین نوری زاده
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 69038
عنوان فارسی مقاله Evaluation of cortical bone thickness of mandible with cone beam computed tomography for orthodontic mini implant installation
عنوان لاتین مقاله Evaluation of cortical bone thickness of mandible with cone beam computed tomography for orthodontic mini implant installation
ناشر 6
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) Advances in Bioscience & Clinical Medicine
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح چهار – سایر سایت های تخصصی
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Background: Achieving maximum anchorage without movement of the teeth in anchorage unit has been a great challenge in orthodontics and the success of the treatment plan highly depends on it. In this case, using orthodontic mini-implants can make a huge difference. The objective of this retrospective study was to measure thickness of cortical bone at prospective mini-implant placement sites in mandible in order to understand stability aspects of miniimplant placement by using cone-beam computed tomography (CBCT) images. Materials and Methods: Initial 3-dimensional images of 40 adult patients were studied. The cortical bone thickness was obtained at the alveolar processes from canine to second molar at 5 different vertical levels from the cementoenamel junction (CEJ). To determine the cortical bone thickness, tangent lines were drawn buccolingually to the roots in axial section and a third line was drawn from the middle of these two lines, and the cortical bone thickness was measured where the third line crossed the buccal cortex. Results: Mandibular and buccal cortical bone thicknesses were 0.79 to 2.49 mm, respectively. There was a statistically significant increase from the CEJ to the apex (P<0.001), while this increase was not statically significant at interdental area of teeth #3 and #4. Comparing the 4 mm section in all sites showed significant increase from anterior to posterior. Conclusion: Based on our results, the cortical bone thickness mostly follows a pattern and depends on the interradicular site rather than individual differences.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
امین نوری زادهسوم
سید حسین مسلم زادهاول
آیدین سهرابیچهارم
یوسف کنعانی زادهدوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
1.pdf1398/07/01565417دانلود