Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns: A finite element analysis

Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns: A finite element analysis


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: محمود رباطی انارکی , علی تراب , تایماز مونسی راد

کلمات کلیدی: Dental implants, finite element analysis, fixed partial denture, fracture strength, zirconia.

نشریه: 19913 , 2 , 13 , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمود رباطی انارکی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 68961
عنوان فارسی مقاله Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns: A finite element analysis
عنوان لاتین مقاله Comparison of stress in implant-supported monolithic zirconia fixed partial dentures between canine guidance and group function occlusal patterns: A finite element analysis
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Background. Monolithic zirconia is an emerging material for crowns and bridges. The possibility of full digital design has made it an attractive alternative material for implant-supported prostheses. A proper design is vital in the success of such a prosthesis like any other. This study, in the shortage of scientific evidence, has tried to assess the stress distribution of occlusal forces inside the implant-prosthesis system of a 3-unit bridge made of monolithic zirconia. Methods. A 3-unit monolithic zirconia bridge supported by two implant fixtures placed on the teeth #13 and #15 was digi-talized. It was converted to a mesh of 59000 nodes and 34000 elements. Five types of occlusal forces (one as vertical centric, two at 15º and 30º simulating canine pattern of lateral movement, and two at 15º and 30º simulating group function pattern) were applied. The stress distribution among all the components of the implant-bridge system was assessed using Ansys Work-bench 14 software and finite element analysis. Results. The maximum stress was between 286 and 546 MPa, which were found in either the fixture‒abutment screw area or in the upper part of the pontic connector between the canine and first premolar. The maximum pressure increased with an increase in the angle of occlusal force. Significantly higher stress was recorded in the group function occlusal pattern. Conclusion. Monolithic zirconia can be promising in designing bridges in the canine‒premolar area. However, proper design is necessary with more attention to the connectors and types of occlusal forces.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
محمود رباطی انارکیاول
علی ترابسوم
تایماز مونسی راددوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
torab.pdf1398/06/24471027دانلود