Comparison of the Spo2/Fio2 Ratio and the Pao2/Fio2 Ratio in Patients with Acute Lung Injury or Acute Respiratory Distress Syndrome

Comparison of the Spo2/Fio2 Ratio and the Pao2/Fio2 Ratio in Patients with Acute Lung Injury or Acute Respiratory Distress Syndrome


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: نعمت بیلان , اذر دسترنجی , افشین قلعه گلاب بهبهانی

کلمات کلیدی: ARDS ALI Pao2 /Fio2 Pulse Oximetry

نشریه: 19063 , 2015 , 7(1) , 2015, 7(1), 28-31 , 2015

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله نعمت بیلان
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات سلامت کودکان
کد مقاله 68761
عنوان فارسی مقاله Comparison of the Spo2/Fio2 Ratio and the Pao2/Fio2 Ratio in Patients with Acute Lung Injury or Acute Respiratory Distress Syndrome
عنوان لاتین مقاله Comparison of the Spo2/Fio2 Ratio and the Pao2/Fio2 Ratio in Patients with Acute Lung Injury or Acute Respiratory Distress Syndrome
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Introduction: Diagnostic criteria for acute lung injury (ALI) and Acute Respiratory Distress syndrome (ARDS) includes acute onset of disease, chest radiograph demonstrating bilateral pulmonary infiltrates, lack of significant left ventricular dysfunction and Pao2 /Fio2 (PF) ratio ≤300 for ALI or ≤200 for ARDS. Recent criteria require invasive arterial sampling. The pulse oximetric saturation Spo2 /Fio2 (SF) ratio may be a reliable non-invasive alternative to the PF ratio. Methods: In this cross-sectional study, we enrolled 70 patients with ALI or ARDS who were admitted in Tabriz children’s hospital pediatrics intensive care unit (PICU). Spo2 , Fio2 , Pao2 , charted within 5 minutes of each other and calculated SF and PF were recorded to determine the relationship between SF and PF ratio. SF values were examined as a substitute of PF ratio for diagnosis ARDS and ALI. Results: The relationship between SF and PF ratio was described by the following regression equation: SF=57+0.61 PF (P<0.001). SF ratios of 181 and 235 corresponded of PF ratio 300 and 200. The SF cutoff of 235 had 57% sensitivity and 100% specificity for diagnosis of ALI. The SF cutoff of 181 had 71% sensitivity and 82% specificity for diagnosis of ARDS. Conclusion: SF ratio is a reliable noninvasive surrogate for PF ratio to identify children with ALI or ARDS with the advantage of replacing invasive arterial blood sampling by non-invasive pulse oximetry.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
نعمت بیلاناول
اذر دسترنجیدوم
افشین قلعه گلاب بهبهانیسوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
maghaleh.pdf1398/06/16331531دانلود