اندازه گیری آتنولول و کارودیلول در فرمولاسیون های داروئی بعد از بهینه سازی پارامترها به روش RSM

Spectrofluorimetric Determination of Atenolol and Carvedilol in Pharmaceutical Preparations after Optimization of Parameters using Response Surface Methodology


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: احد باویلی تبریزی

کلمات کلیدی: Ammonia, Berthelot reaction, exhaled breath condensate (EBC), nitrite, spectrophotometry

نشریه: 0 , 25 , 3 , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله احد باویلی تبریزی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده داروسازی
کد مقاله 68660
عنوان فارسی مقاله اندازه گیری آتنولول و کارودیلول در فرمولاسیون های داروئی بعد از بهینه سازی پارامترها به روش RSM
عنوان لاتین مقاله Spectrofluorimetric Determination of Atenolol and Carvedilol in Pharmaceutical Preparations after Optimization of Parameters using Response Surface Methodology
ناشر 2
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) Pharmaceutical Sciences
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح سه – Scopus
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract: Background: Exhaled breath has recently been identified as an alternative matrix for the detection of drugs and chemical compounds. By keeping in mind that different chemical and biological compounds have already been determined in the exhaled air, the exhaled breath condensate (EBC) was found to be a suitable sample for non-invasive assessment of the respiratory system. Thus, the aim of this work is determination of ammonia and nitrite in EBC samples. Methods: The determination of the analytes is based on the derivatization of ammonia using Berthelot method. The absorbance of colored compound was determined at 655 ± 3 nm. Nitrite ion was determined after its reduction to ammonia by using Zn/HCl reagent. Results: Good calibration curves were obtained for ammonia with linearity in the range of 10– 620 ng mL -1 , and correlation coefficients (R2) of more than 0.999. The limit of detection and quantification (LOD, LOQ) and lower limit of quantification (LLOQ) were found to be 1.5, 4.5 and 10 ng mL -1 , respectively. The recoveries of the method were calculated to be 94 to 102.5% and the intra- and inter-day precisions were lower than 1.4 and 3.4%, respectively. Conclusion: The results presented here demonstrate that the concentrations of ammonia and nitrite in samples of healthy humans can be determined with good accuracy, high sensitivity, and simple operation. The proposed EBC methodology possessed several advantages like simplicity and low cost, especially if more sophisticated techniques such as HPLC are not available.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
احد باویلی تبریزیاول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
25(3)11-Proof.pdf1398/06/05463803دانلود