A single-shot diagnostic platform based on copper nanoclusters coated with cetyl trimethylammonium bromide for determination of carbamazepine in exhaled breath condensate.
A single-shot diagnostic platform based on copper nanoclusters coated with cetyl trimethylammonium bromide for determination of carbamazepine in exhaled breath condensate.
نویسندگان: آیدا هاتفی , الهه رحیم پور , مریم خوب نسب جعفری , مریم عدالت , وحید جویبان قراملکی , سیما الوانی علمداری , ابوالقاسم جویبان
کلمات کلیدی: Carbamazepine . Copper . Nanoprobe . Nanocluster . Fluorescence . Response surface methodology . Central
composite design
نشریه: 0 , 0 , 186 , 2019
| نویسنده ثبت کننده مقاله |
الهه رحیم پور |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات آنالیز دارویی |
| کد مقاله |
68453 |
| عنوان فارسی مقاله |
A single-shot diagnostic platform based on copper nanoclusters coated with cetyl trimethylammonium bromide for determination of carbamazepine in exhaled breath condensate. |
| عنوان لاتین مقاله |
A single-shot diagnostic platform based on copper nanoclusters coated with cetyl trimethylammonium bromide for determination of carbamazepine in exhaled breath condensate. |
| ناشر |
9 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
Microchimica Acta |
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح یک – ISI - Web of Science |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| A fluorescent nanoprobe is designed for the determination of carbamazepine (CBZ) in exhaled breath condensate (EBC) of
patients receiving CBZ. The probe consists of copper nanoclusters (Cu NCs) coated with cetyl trimethylammonium bromide. The
interaction of probe with CBZ results in blocking non-radiative e
−
/h + recombination defect sites on the surface of Cu NCs and
consequently enhancing the blue-green fluorescence of Cu NCs (excitation/emission wavelengths: 290/480 nm). The experi-
mental conditions were optimized using a response surface methodology (central composite design). Under the optimized
conditions, the calibration plot is linear in the 0.2 to 20 μg mL
−1 CBZ concentration range and the detection limit is as low as
0.08 μg mL
−1 . The intra-day and inter-day relative standard deviations for six replicated measurements of 10 μg mL
−1 CBZ are
3.9% and 4.8%, respectively. The method was applied for the determination of CBZ level in EBC of patients receiving CBZ. The
accuracy of the method was confirmed by HPLC-UV analysis as a reference method. |