Finite Element Analysis of Soft-lined Mandibular Complete Denture and its Supporting Structures

Finite Element Analysis of Soft-lined Mandibular Complete Denture and its Supporting Structures


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: کتایون صدر

کلمات کلیدی: Complete denture, soft liner, finite element analysis

نشریه: 19913 , 2 , 6 , 2012

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله کتایون صدر
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 67824
عنوان فارسی مقاله Finite Element Analysis of Soft-lined Mandibular Complete Denture and its Supporting Structures
عنوان لاتین مقاله Finite Element Analysis of Soft-lined Mandibular Complete Denture and its Supporting Structures
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Background and aims. There are many edentulous people with severely resorbed residual ridges and non-resilient lin-ing mucosa that are unable to tolerate occlusal forces during functional and parafunctional movements. Lining the tissue surface of dentures with a flexible material can theoretically distribute and absorb forces with cushioning effect. The aim of this study was to evaluate the effect of a soft liner on stress levels in mandibular complete denture and its supporting struc-tures by finite element analysis. Materials and methods. A simplified 3-dimensional finite element model of relatively resorbed mandible, mucosa, denture and a soft liner was prepared. Then the model, with and without soft liner, underwent normal vertical and lateral occlusal forces. The stresses were analyzed using the ANSYS 12 software. Results. Using the soft liner increased stress levels up to 18.5% and 30% in the cortical bone and mucosa, respectively, after vertical load was applied in the incisor region. Application of bilateral vertical load on the molar area increased stress in cortical bone u to 44% and in the mucosa up to 29%. Unilateral loading in the canine area increased stress level in the mucosa up to 63.5%. The highest stress was seen at denture base followed by the cortical bone. Conclusion. Use of soft liners increased stress in denture supporting structures. Higher level of stress concentration was observed primarily in the denture base followed by the cortical bone.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
کتایون صدراول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
320-3460-2-PB.pdf1398/04/233750622دانلود