Evaluation of CT calibration curves from stoichiometric and tissue substitute methods according to tissue characteristics

Evaluation of CT calibration curves from stoichiometric and tissue substitute methods according to tissue characteristics


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: ایمان امینی , پریسا اخلاقی

کلمات کلیدی: CT calibration curve / electron density / physical phantom / stoichiometric calibration / tissue substitute method

نشریه: 29075 , 2 , 54 , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله پریسا اخلاقی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز تحقیقات ایمونولوژی
کد مقاله 67127
عنوان فارسی مقاله Evaluation of CT calibration curves from stoichiometric and tissue substitute methods according to tissue characteristics
عنوان لاتین مقاله Evaluation of CT calibration curves from stoichiometric and tissue substitute methods according to tissue characteristics
ناشر 2
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

In order to optimize and increase the precision of dose determination, it is important to obtain the relationship between CT Hounsfield units and electron densities, as the basic inputs for radiotherapy planning systems. Therefore, the aim of this study was to plot and compare the CT calibration curves resulted from both tissue substitute calibration (based on the tissue equivalent materials) and stoichiometric calibration (based on biological tissues) methods for a specific CT scanner at tube voltage of 120 kVp by applying a precise homemade physical phantom. Hence, the Hounsfield units of all phantom materials were measured experimentally and also calculated by related formulas. Considering the CT numbers and the electron densities of various tissue equivalent materials and real tissues, the calibration curves were plotted. According to the results, the higher accuracy of the stoichiometric method relative to tissue substitute method was confirmed in this study. On the other hand, since estimating Hounsfield unit of each human tissue strongly depends on the physical properties of tissue substitutes of the physical phantom, the high precision of this phantom led to increase the accuracy of the calibration curves obtained based on the stoichiometric method.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
ایمان امینیاول
پریسا اخلاقیدوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
radiopro180050.pdf1398/03/081075492دانلود