Treatment Results of Bicondylar Tibial Fractures Using Hybrid External Fixator

Treatment Results of Bicondylar Tibial Fractures Using Hybrid External Fixator


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: جعفر گنج پور ثالث , جعفر سلیمانپور مختار مانند , معروف انصاری

کلمات کلیدی: Tibial condyle fracture, Hybrid External Fixator , Tibial plateau Fracture. Complication.

نشریه: 26644 , 10 , 16 , 2013

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله معروف انصاری
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده پیراپزشکی
کد مقاله 66919
عنوان فارسی مقاله Treatment Results of Bicondylar Tibial Fractures Using Hybrid External Fixator
عنوان لاتین مقاله Treatment Results of Bicondylar Tibial Fractures Using Hybrid External Fixator
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح سه – Scopus
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract: Tibial condyle fractures affect knee stability and motion. Treatment of bicondylar type of tibial plateau fracture is a challenging problem. This study aimed at evaluating the application of hybrid external fixators with minimum deformation in these patients and the resulted outcomes. In this descriptive analytical study, 28 patients with bicondylar tibial plateau fractures treated by HEF device were evaluated. The surgeon used a semicircular and one circular wire instead of the one or two loop of conventional HEF device for a better range of motion of the knee joint. Treatment outcomes including quality of walking, union condition, knee range of motion, complications and the final outcome according to the knee score (rusmussen) were checked. Twenty-eight male patients, with the mean age of 40.54±13.83 years were enrolled in the study. Complications occurred in 8 (28.6%) patients; 7 cases with superficial infection and 1 patient with deep vein thrombosis. All complications were managed medically with no significant consequences left. All the patients were able to walk with no aid except in one case. In 96.4% and 89.3% of the cases, the clinical and radiological outcomes were good to excellent, respectively according to the knee score. In 85.7% of the patients, the knee range of motion was in normal limits. Application of hybrid external fixator using one and half ring instead of one or two fixator rings in treating bicondylar tibial fractures was associated with desired clinical and radiological results.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
جعفر گنج پور ثالثاول
جعفر سلیمانپور مختار ماننددوم
معروف انصاریسوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
treatment.pdf1398/02/30139017دانلود