Effect of electric currents on antibacterial effect of chlorhexidine against Entrococcus faecalis biofilm: An in vitro study.
Effect of electric currents on antibacterial effect of chlorhexidine against Entrococcus faecalis biofilm: An in vitro study.
نویسندگان: امین سالم میلانی , ایسان مظفری , محمد حسین سروش برحقی , محمد فروغ ریحانی
کلمات کلیدی: Biofilm, Chlorhexidine, Direct current, Electric current, Enterococcus faecalis
نشریه: 19695 , 12 , 10 , 2018
| نویسنده ثبت کننده مقاله |
محمد فروغ ریحانی |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
دانشکده دندانپزشکی |
| کد مقاله |
66881 |
| عنوان فارسی مقاله |
Effect of electric currents on antibacterial effect of chlorhexidine against Entrococcus faecalis biofilm: An in vitro study. |
| عنوان لاتین مقاله |
Effect of electric currents on antibacterial effect of chlorhexidine against Entrococcus faecalis biofilm: An in vitro study. |
| ناشر |
4 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
|
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح دو – PubMed |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| Background: This in vitro study was mainly aimed to evaluate the effect of high-frequency alternating currents
(AC) applied by an electronic apex locator (EAL) on the antibacterial properties of chlorhexidine (CHX) on E.
faecalis biofilm.
Material and Methods: The root canals of 120 extracted human single-rooted teeth were prepared using Gates-Glidden drills and hand K-files. After contaminating the root canals with E. faecalis, they were incubated for 60 days.
Then, the teeth were randomly divided into six experimental groups (n=20). Group 1, 2% CHX; group 2, normal
saline (NS) with direct current (DC); group 3, normal saline (NS) with high-frequency alternating current (AC);
group 4, 2% CHX with DC; group 5, 2% CHX with AC; group 6, control (normal saline). The samples were collected from the root canal walls of 16 teeth in each group and 1:10 serial dilutions were prepared and added to
Muller-Hinton agar (MHA) plates and incubated at 37°C for 48 h. The longitudinal sections of the other 4 teeth
used to observe under a scanning electron microscope (SEM). A classic colony counting technique was used for
counting the vital E. faecalis bacteria in MHA. Two-way ANOVA was used for statistical analysis of the data. The
level of significance was set at P<0.05.
Results: The electric current significantly changed the colony-forming units (CFU) values (P<0.001). According
to pair-wise comparisons, the highest CFU difference was observed between the AC group and the group without
electric current (P<0.001); furthermore, the difference between the DC group and the group without electric current
was not significant (P=0.823).
Conclusion: The highest bioelectric effect occurred with the use of high-frequency alternating electric current in the
form of an apex locator with CHX as a canal irrigant. |