The effect of microthread design on magnitude and distribution of stresses in bone: A three-dimensional finite element analysis

The effect of microthread design on magnitude and distribution of stresses in bone: A three-dimensional finite element analysis


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: عدیله شیرمحمدی

کلمات کلیدی: Bone; dental implant-abutment design; finite element analysis; mechanical; stress

نشریه: 43816 , 15 , 5 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله عدیله شیرمحمدی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 66842
عنوان فارسی مقاله The effect of microthread design on magnitude and distribution of stresses in bone: A three-dimensional finite element analysis
عنوان لاتین مقاله The effect of microthread design on magnitude and distribution of stresses in bone: A three-dimensional finite element analysis
ناشر 5
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

BACKGROUND: The researches regarding the influence of microthread design variables on the stress distribution in bone and a biomechanically optimal design for implant neck are limited. The aim of the present study is to compare the effect of different microthread designs on crestal bone stress. MATERIALS AND METHODS: Six implant models were constructed for three-dimensional finite element analysis including two thread profile (coarse and fine) with three different lengths of microthreaded neck (1 mm, 2 mm, and 3 mm). A load of 200 N was applied in two angulations (0° and 30°) relative to the long axis of the implant and the resultant maximum von Mises equivalent (EQV), compressive, tensile, and shear stresses were measured. RESULTS: Regardless of loading angle, the highest EQV stress was concentrated in the cortical bone around the implant model using a 1 mm neck of fine microthreads. Under axial loading, there was a negative correlation between the length of the microthreaded neck and stress level in both profiles. However, the same pattern was not observed for coarse microthreads under oblique loads. All types of measured stresses in all constructed models were increased with oblique loading. CONCLUSION: Peak stress levels in implant models varied with microthread profile and direction of loading. The microthread profile seemed more important than the length of the neck in reducing loading stresses exerted on the surrounding bone. Fine microthreads on a 3 mm implant neck showed consistently higher cortical bone stress than other models.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
عدیله شیرمحمدیچهارم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
The_effect_of_microthread_design_on_magnitude_and_.pdf1398/02/251310270دانلود