Surface Roughness of Different Composite Resins After Application of 15% Carbamide Peroxide and Brushing with Toothpaste: An In-Vitro Study
Surface Roughness of Different Composite Resins After Application of 15% Carbamide Peroxide and Brushing with Toothpaste: An In-Vitro Study
نویسندگان: المیرا جعفری نویمی پور , امیر احمد عجمی , سیاوش سوادی اسکویی , مهدی عابد کهنمویی , محمود بهاری , محمد اسماعیل ابراهیمی چهارم
کلمات کلیدی: Tooth Bleaching; Surface Properties; Composite Resins; Toothbrushing; Toothpastes
نشریه: 19918 , 1 , 9 , 2019
| نویسنده ثبت کننده مقاله |
المیرا جعفری نویمی پور |
| مرحله جاری مقاله |
تایید نهایی |
| دانشکده/مرکز مربوطه |
مرکز تحقیقات لثه و دندان |
| کد مقاله |
66669 |
| عنوان فارسی مقاله |
Surface Roughness of Different Composite Resins After Application of 15% Carbamide Peroxide and Brushing with Toothpaste: An In-Vitro Study |
| عنوان لاتین مقاله |
Surface Roughness of Different Composite Resins After Application of 15% Carbamide Peroxide and Brushing with Toothpaste: An In-Vitro Study |
| ناشر |
7 |
| آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ |
بلی |
| عنوان نشریه (خارج از لیست فوق) |
Frontiers in Dentistry |
| نوع مقاله |
Original Article |
| نحوه ایندکس شدن مقاله |
ایندکس شده سطح دو – PubMed |
| آدرس لینک مقاله/ همایش در شبکه اینترنت |
|
| Abstract Objectives: This study aimed to evaluate the effect of toothbrushing after application of 15% carbamide peroxide (CP) on the surface roughness of three types of composite resins. Materials and Methods: Twenty samples, measuring 4 mm in height and diameter, were fabricated of three composite resins namely microfilled (MF) Heliomolar HB, nanohybrid (NH) IPS Empress Direct and microhybrid (MH) Tetric Ceram HB. After polishing, the initial surface roughness was measured with a profilometer. The tray technique was used to apply 15% CP gel for 6 hours. Then, cleaning was carried out with an Oral-B electric toothbrush for 3 minutes in a tank containing a freshly mixed toothpaste. These procedures were repeated for 21 days. Then, the surface roughness was measured again and compared with the initial values. A mixed-design ANOVA model was used for the analysis of data (P<0.05). Results: The baseline roughness was significantly lower in MF compared to the NH and MH composites (P<0.001). Roughness increased in all study groups during the intervention period; however, this increase was not significant in the MH group (P=0.17). Furthermore, the increase in roughness in MF was smaller than that in NH (P<0.001) and MH (P=0.02) groups. Conclusions: The effect of intervention was more pronounced on NH and MH groups. Surface roughness changes were minor in MF composite resin. |
| نام فایل |
تاریخ درج فایل |
اندازه فایل |
دانلود |
| 2585-Full Text-15545-2-10-20190507.pdf | 1398/02/18 | 838822 | دانلود |