Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study

Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: سعید رحیمی دره چی , پریا داودی باویل علیایی , وحید زند

کلمات کلیدی: Electronic apex locator; NovApex Root-ZX

نشریه: 19841 , 5 , 18 , 2017

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله وحید زند
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 66624
عنوان فارسی مقاله Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study
عنوان لاتین مقاله Accuracy of Working Length Determination using NovApex and Root-ZX Apex Locators: An in vitro Study
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Abstract INTRODUCTION: This ex vivo study evaluated the accuracy of the Root-ZX electronic apex locator (EAL) (J. Morita, Tokyo, Japan) and the NovApex (Forum Technologies, Rishon Lezion, Israel) in determining the working length (WL) during endodontic treatment. MATERIALS AND METHODS: Forty extracted single-rooted human teeth were selected for this study. The actual WL was measured with visual technique by a size #15 k-file under magnification. Then, the canal lengths were measured electronically with both Root-ZX and NovApex apex locators within ±0.5 and ±1 mm. Mean percentage of data was analyzed between groups using paired t-test, with a statistically significant level of p < 0.05. RESULTS: The accuracy of NovApex apex locator was 85% within ±0.5 mm and 92.5% within ±1 mm. The accuracy of Root-ZX apex locator was 70% within ±0.5 mm and 97.5% within ±1 mm. There was no significant difference between the accuracy of the two EALs. CONCLUSION: Both the NovApex and Root-ZX EALs are useful for measuring the WL with high accuracy. CLINICAL SIGNIFICANCE: Given the importance of accurate WL determination in the success of endodontic treatments, the accuracy of different apex locators should be evaluated

نویسندگان
hide/show

نویسنده نفر چندم مقاله
سعید رحیمی دره چیدوم
پریا داودی باویل علیاییسوم
وحید زنداول

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
1.pdf1398/02/28518212دانلود