Corrosion Behavior of a Nickel-Base Dental Casting Alloy in Artificial Saliva Studied by Weight Loss and Polarization Technique

Corrosion Behavior of a Nickel-Base Dental Casting Alloy in Artificial Saliva Studied by Weight Loss and Polarization Techniques


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: الناز مصلحی فرد

کلمات کلیدی: Corrosion; Nickel-Chromium Alloys; Artificial Saliva; Polarization; Weight Loss

نشریه: 0 , 1 , 16 , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله الناز مصلحی فرد
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه دانشکده دندانپزشکی
کد مقاله 66346
عنوان فارسی مقاله Corrosion Behavior of a Nickel-Base Dental Casting Alloy in Artificial Saliva Studied by Weight Loss and Polarization Technique
عنوان لاتین مقاله Corrosion Behavior of a Nickel-Base Dental Casting Alloy in Artificial Saliva Studied by Weight Loss and Polarization Techniques
ناشر 4
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق) Frontiers in Dentistry (Formerly known as :Journal of Dentistry of Tehran University of Medical Sciences (JDT))
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح دو – PubMed
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Objectives: Nickel-chromium (Ni-Cr) base dental alloys with desirable properties have been employed in prosthodontics for years. Corrosion behavior of a Ni-Cr base alloy in artificial saliva with different pH values is determined in this work. Materials and Methods: Corrosion behavior of Ni-Cr alloy was studied using weight loss described by corrosion rate (CR) in mils per year (mpy) and potentiodynamic polarization described by corrosion potential (CP) in mV and current density (CD) in mA/cm2 in artificial saliva with different pH. Surface morphology was studied using scanning electron microscopy (SEM). Statistical difference was assessed using oneway ANOVA and post-hoc Tukey's honestly significant difference (HSD) test with a difference significance of 95%. Results: In weight loss method, CR was 71.95±3.40, 17.26±1.03, 8.92±0.35, and 6.93±0.54 mpy at pH values of 2.5, 5, 7, and 9, respectively. CR obtained at pH of 2.5 was significantly different than that in other groups, but those obtained at pH of 5, 7, and 9 were not significantly different. In the polarization method, CP values were significantly different. CD measured at pH of 2.5 and 5 was significantly different than the rest of pH values (P<0.05). CRs at pH of 7 and 9 were not significantly different. SEM exhibited the formation of preferential sites of corrosion attacks influenced by pH. Conclusions: Both techniques revealed consistent results. Corrosion resistance increases as pH increases towards less acidic conditions. In more acidic saliva, the corrosion rate is greater. The less acidic saliva leads to formation of a more stable passive film on Ni, and the dissolution of Ni decreases, leading to lower CRs.