Use of bismuth shield for protection of superficial radiosensitive organs in patients undergoing computed tomography: a literature review and meta-analysis

Use of bismuth shield for protection of superficial radiosensitive organs in patients undergoing computed tomography: a literature review and meta-analysis


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: رضا ملک زاده , محمد یوسفی سوته , پریناز محنتی

کلمات کلیدی: Bismuth shielding · Computed tomography · Dose reduction · Image quality

نشریه: 29066 , 12 , 12 , 2019

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله پریناز محنتی
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه تیم های تحقیقاتی دانشگاه
کد مقاله 66151
عنوان فارسی مقاله Use of bismuth shield for protection of superficial radiosensitive organs in patients undergoing computed tomography: a literature review and meta-analysis
عنوان لاتین مقاله Use of bismuth shield for protection of superficial radiosensitive organs in patients undergoing computed tomography: a literature review and meta-analysis
ناشر 3
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ بلی
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Review Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

The study aimed to assess the effect of bismuth (Bi) shielding on dose reduction and image quality in computed tomography (CT) through a literature review. A search was conducted in the following databases: Web of Science, PubMed, Google Scholar, and Scopus. Studies that reported estimated dose reduction with bismuth shielding during imaging of the eye, thyroid, and breast were included, and a meta-regression analysis was used to examine the influence of the CT scanner type on the dose reduction. The studies included a total of 237 patients and 34 pediatric and adult anthropomorphic phantoms for whom the radiation dose was reported. Bismuth shielding was recommended in 88.89% of the studies based on the maintenance of appropriate image quality under shielding. Noise associated with Bi shielding was 7.5%, 263%, and 23.5% for the eye, thyroid, and breast, respectively. The fixed-effects pooled estimate of dose reduction was 34% (95% CI: 13–55; p < 0.001) for the eye, 37% (95% CI 14–61; p < 0.001) for the thyroid, and 36% (95% CI 36–55; p < 0.001) for the breast. The image quality, usage of foams, CT scanner type, beam energies, and backscatter radiation were important factors that directly affected the efficacy of Bi shielding to reduce the radiation dose at the superficial radiosensitive organs.