Diagnostic Accuracy of a 64-Slice Multi-Detector CT Scan in the Preoperative Evaluation of Periampullary Neoplasms

Diagnostic Accuracy of a 64-Slice Multi-Detector CT Scan in the Preoperative Evaluation of Periampullary Neoplasms


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: شهریار هاشم زاده , رضا جواد رشید , فاطمه صیفار , فرید حاجی بنابی , فرزاد کاکائی

کلمات کلیدی: diagnosis; multi-detector computed tomography; pancreas; periampullary carcinoma

نشریه: 0 , 91 , 7 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله فاطمه صیفار
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه مرکز سلولهای بنیادی
کد مقاله 65278
عنوان فارسی مقاله Diagnostic Accuracy of a 64-Slice Multi-Detector CT Scan in the Preoperative Evaluation of Periampullary Neoplasms
عنوان لاتین مقاله Diagnostic Accuracy of a 64-Slice Multi-Detector CT Scan in the Preoperative Evaluation of Periampullary Neoplasms
ناشر 8
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق) Journal of Clinical Medicine
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Periampullary tumors are highly malignant masses with poor prognosis. Surgical resection is the only treatment for patients with this disease. The preoperative evaluation of masses is essential to determine the tumor resectability and vascular invasion. The aim of this study was to determine the diagnostic accuracy of 64-slice multi-detector computed tomography (MDCT) in detecting the resectability of periampullary masses. A cross-sectional study was conducted on patients with a definite diagnosis of periampullary cancer. All the participants underwent an MDCT scan before the surgical pancreaticoduodenectomy. The preoperative results were compared to the intraoperative findings and the diagnostic accuracy was determined based on the sensitivity and specificity of the MDCT. From June 2015 until June 2016, 32 patients with periampullary carcinoma were enrolled in the study. Of 32 masses, one of them considered nonresectable because of the gross vascular invasion in th CT images. After the operation, the overall resectability rate was 81.3%. The sensitivity and specificity of MDCT for tumor resectability was 100% and 16.7%, respectively, with an overall accuracy of 84.4%. To sum up, MDCT had high sensitivity but low specificity in the preoperative evaluation of preampullary carcinomas. The low specificity resulted from the low accuracy of the CT scan in detecting vascular involvement.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
شهریار هاشم زادهاول
رضا جواد رشیدچهارم
فاطمه صیفارششم
فرید حاجی بنابیهفتم
فرزاد کاکائیدوم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
jcm-07-00091-v2.pdf1397/09/18511171دانلود
IMG-20181026-WA0000.jpg1397/09/1848788دانلود