Preoperative Multi-Detector Computed Tomography in Kidney Donors; Quantitative Data Report from Operation Rooms

Preoperative Multi-Detector Computed Tomography in Kidney Donors; Quantitative Data Report from Operation Rooms


چاپ صفحه
پژوهان
صفحه نخست سامانه
چکیده مقاله
چکیده مقاله
نویسندگان
نویسندگان
دانلود مقاله
دانلود مقاله
دانشگاه علوم پزشکی تبریز
دانشگاه علوم پزشکی تبریز

نویسندگان: رضا پیری , محمد نقوی بهزاد , نریمان نظامی , محمد کاظم طرزمنی

کلمات کلیدی: Keywords: Computed Tomography, Angiography, Kidney, Artery

نشریه: 16604 , 4 , 15 , 2018

اطلاعات کلی مقاله
hide/show

نویسنده ثبت کننده مقاله محمد نقوی بهزاد
مرحله جاری مقاله تایید نهایی
دانشکده/مرکز مربوطه کمیته تحقیقات دانشجویی
کد مقاله 64572
عنوان فارسی مقاله Preoperative Multi-Detector Computed Tomography in Kidney Donors; Quantitative Data Report from Operation Rooms
عنوان لاتین مقاله Preoperative Multi-Detector Computed Tomography in Kidney Donors; Quantitative Data Report from Operation Rooms
ناشر 9
آیا مقاله از طرح تحقیقاتی و یا منتورشیپ استخراج شده است؟ خیر
عنوان نشریه (خارج از لیست فوق)
نوع مقاله Original Article
نحوه ایندکس شدن مقاله ایندکس شده سطح یک – ISI - Web of Science
آدرس لینک مقاله/ همایش در شبکه اینترنت

خلاصه مقاله
hide/show

Background: Multi-detector computed tomography (MDCT) angiography is a non-invasive imaging modality, and is replacing the invasive conventional angiography in preoperative studies of vascular anatomy. Objectives: To determine the accuracy of MDCT in diagnosis of the renal arterial and venous anatomy, urinary collecting system and kidney anatomy itself in living kidney donors. Patients and Methods: In the present prospective single-center study, 134 potential kidney donors (age: 25.65 ± 3.37 years) under- went MDCT and MDCT angiography in a single center (Aug 2012 - Oct 2013). The bolus tracking method was used. Arterial and venous anatomical variations and kidney size were assessed and compared with the surgical findings. Results: MDCT angiography revealed renal arteries, their branching with 100% sensitivity, specificity, positive and negative pre- dictive values. In addition, the sensitivity, specificity, positive predictive value and negative predictive value for MDCT angiography were 85.71%, 100%, 100% and 99.14%, respectively, in diagnosis of venous branching pattern. There is direct linear correlation between MDCT angiography and surgical findings in measuring arterial length and diameter, and kidney size (All P values < 0.001). Only one patient had ureteral duplication. Conclusion: MDCT determines the renal vascular and urinary collecting system anatomy, and kidney characteristics with almost 100% accuracy in kidney donors.

نویسندگان
hide/show

نویسنده نفر چندم مقاله
رضا پیریسوم
محمد نقوی بهزاددوم
نریمان نظامیاول
محمد کاظم طرزمنیهشتم

لینک دانلود مقاله
hide/show

نام فایل تاریخ درج فایل اندازه فایل دانلود
iranjradiol-15-4-59025.pdf1397/08/133608633دانلود
111.pdf1397/08/13263882دانلود
11.jpg1397/08/15187624دانلود